CVE-2015-3963

Severity CVSS v4.0:
Pending analysis
Type:
CWE-330 Use of Insufficiently Random Value
Publication date:
04/08/2015
Last modified:
12/04/2025

Description

Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.

Vulnerable products and versions

CPE From Up to
cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:* 6.5 (including) 6.6 (including)
cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:* 6.7 (including) 6.7.1.1 (excluding)
cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:* 6.8 (including) 6.8.3 (excluding)
cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:* 6.9 (including) 6.9.4.4 (excluding)
cpe:2.3:o:windriver:vxworks:6.6.3:*:*:*:cert:*:*:*
cpe:2.3:o:windriver:vxworks:6.6.4:*:*:*:cert:*:*:*
cpe:2.3:o:windriver:vxworks:6.6.4.1:*:*:*:cert:*:*:*
cpe:2.3:o:windriver:vxworks:7.0:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:sage_1210:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:sage_1230:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:sage_1250:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:sage_1310:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:sage_1330:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:sage_1350:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*