CVE-2022-31795

Severity CVSS v4.0:
Pending analysis
Type:
CWE-78 OS Command Injections
Publication date:
20/06/2022
Last modified:
27/06/2022

Description

An issue was discovered on Fujitsu ETERNUS CentricStor CS8000 (Control Center) devices before 8.1A SP02 P04. The vulnerability resides in the grel_finfo function in grel.php. An attacker is able to influence the username (user), password (pw), and file-name (file) parameters and inject special characters such as semicolons, backticks, or command-substitution sequences in order to force the application to execute arbitrary commands.

Vulnerable products and versions

CPE From Up to
cpe:2.3:o:fujitsu:eternus_cs8000_firmware:*:*:*:*:*:*:*:* 8.1 (excluding)
cpe:2.3:o:fujitsu:eternus_cs8000_firmware:8.1:-:*:*:*:*:*:*
cpe:2.3:h:fujitsu:eternus_cs8000:-:*:*:*:*:*:*:*