CVE-2025-11780
Severity CVSS v4.0:
HIGH
Type:
CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Publication date:
02/12/2025
Last modified:
03/12/2025
Description
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter.
Impact
Base Score 4.0
8.70
Severity 4.0
HIGH
Base Score 3.x
9.80
Severity 3.x
CRITICAL
Vulnerable products and versions
| CPE | From | Up to |
|---|---|---|
| cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:* | ||
| cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:* | ||
| cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:* | ||
| cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:* |
To consult the complete list of CPE names with products and versions, see this page