Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2026-44104

Publication date:
30/07/2026
The firmware update process for the basemodule of the charging controller only validates the<br /> CRC32 checksum without cryptographic signature verification. This allows an unauthenticated remote attacker to install a modified firmware, resulting in full system compromise.
Severity CVSS v4.0: CRITICAL
Last modification:
30/07/2026

CVE-2026-44102

Publication date:
30/07/2026
An unauthenticated remote attacker can trigger a firmware update download via the OCPP backend by supplying an invalid firmware file. This will cause the file to remain accessible for a short period before it is deleted due to improper locking during the cleanup process.
Severity CVSS v4.0: MEDIUM
Last modification:
30/07/2026

CVE-2026-44101

Publication date:
30/07/2026
Due to missing authentication the CHARX OCPP Agent service allows an unauthenticated remote attacker to reconfigure the backend connection. This can lead to Denial-of-Service and confidential data being disclosed to the attacker.
Severity CVSS v4.0: CRITICAL
Last modification:
31/07/2026

CVE-2026-44093

Publication date:
30/07/2026
A local privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
Severity CVSS v4.0: HIGH
Last modification:
30/07/2026

CVE-2026-44095

Publication date:
30/07/2026
A privilege escalation vulnerability in a script used for network configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
Severity CVSS v4.0: HIGH
Last modification:
30/07/2026

CVE-2026-44098

Publication date:
30/07/2026
This vulnerability allows an unauthenticated remote attacker with control over the OCPP backend via firewall-bypass to perform an OS command injection, resulting in the execution of arbitrary commands as the limited user charx-oa. Charging could be interrupted.
Severity CVSS v4.0: HIGH
Last modification:
30/07/2026

CVE-2026-44094

Publication date:
30/07/2026
An unauthenticated remote attacker can enforce the system to fall back to a firmware partition with an insecure configuration including default credentials. This could allow the attacker to gain SSH access to the system as an unprivileged user "user-app". Charging could be interrupted.
Severity CVSS v4.0: HIGH
Last modification:
30/07/2026

CVE-2026-44092

Publication date:
30/07/2026
An unauthenticated remote attacker can inject malicious input into the ModbusServer application because it does not validate the input it fetches from MQTT. This may lead to integrity and availability loss.
Severity CVSS v4.0: HIGH
Last modification:
30/07/2026

CVE-2026-44097

Publication date:
30/07/2026
A low-privileged remote attacker with "operator" access can upload arbitrary files via the REST endpoint intended for firmware updates, resulting in persistent storage of attacker-controlled files and potentially exhausting resources, which might lead to Denial-of-Service.
Severity CVSS v4.0: MEDIUM
Last modification:
30/07/2026

CVE-2026-44096

Publication date:
30/07/2026
A privilege escalation vulnerability in udhcpc allows a local user "charx-web" to execute arbitrary commands as root, resulting in full system compromise.
Severity CVSS v4.0: HIGH
Last modification:
31/07/2026

CVE-2026-13584

Publication date:
30/07/2026
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, Industrial Computer MELIPC series, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Master/Local module Designated communication LSI, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.
Severity CVSS v4.0: HIGH
Last modification:
04/08/2026

CVE-2026-44090

Publication date:
30/07/2026
Due to missing authentication, an unauthenticated remote attacker may access the MQTT broker, which is only protected from external access by a firewall. This may lead to the device being fully compromised.
Severity CVSS v4.0: CRITICAL