CVE-2018-14827
Severity CVSS v4.0:
Pending analysis
Type:
CWE-400
Uncontrolled Resource Consumption ('Resource Exhaustion')
Publication date:
20/09/2018
Last modified:
09/10/2019
Description
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality.
Impact
Base Score 3.x
7.50
Severity 3.x
HIGH
Base Score 2.0
5.00
Severity 2.0
MEDIUM
Vulnerable products and versions
| CPE | From | Up to |
|---|---|---|
| cpe:2.3:a:rockwellautomation:rslinx:*:*:*:*:classic:*:*:* | 4.00.01 (including) |
To consult the complete list of CPE names with products and versions, see this page