CVE-2018-19441

Severity CVSS v4.0:
Pending analysis
Type:
CWE-330 Use of Insufficiently Random Value
Publication date:
27/01/2020
Last modified:
05/02/2020

Description

An issue was discovered in Neato Botvac Connected 2.2.0. The GenerateRobotPassword function of the NeatoCrypto library generates insufficiently random numbers for robot secret_key values used for local and cloud authentication/authorization. If an attacker knows the serial number and is able to estimate the time of first provisioning of a robot, he is able to brute force the generated secret_key of the robot. This is because the entropy of the secret_key exclusively relies on these two values, due to not seeding the random generator and using several constant inputs for secret_key computation. Serial numbers are printed on the packaging and equal the MAC address of the robot.

Vulnerable products and versions

CPE From Up to
cpe:2.3:o:neatorobotics:botvac_connected_firmware:2.2.0:*:*:*:*:*:*:*
cpe:2.3:h:neatorobotics:botvac_connected:-:*:*:*:*:*:*:*