Description

For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, when changing the name of a share, an attacker can craft a command injection payload using backtick "``" characters in the name parameter. As a result, arbitrary commands may be executed as the root user. The attack requires a value __c and iomega parameter.

Vulnerable products and versions

CPE From Up to
cpe:2.3:o:lenovo:lenovoemc_firmware:*:*:*:*:*:*:*:* 4.1.402.34662 (including)
cpe:2.3:h:lenovo:iomega_ez_media_\&_backup_center:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_ix2:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_ix2-dl:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_ix4-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px12-400r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px12-450r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px2-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px4-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px4-300r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px6-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovo_ez_media_\&_backup_center:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovo_ix2:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovo_ix4-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px12-400r:-:*:*:*:*:*:*:*