CVE-2019-18340

Severity CVSS v4.0:
Pending analysis
Type:
CWE-327 Use of a Broken or Risky Cryptographic Algorithm
Publication date:
12/12/2019
Last modified:
09/01/2024

Description

A vulnerability has been identified in Control Center Server (CCS) (All versions = V1.5.0), SiNVR/SiVMS Video Server (All versions = V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store<br /> user and device passwords by applying weak cryptography.<br /> <br /> A local attacker could exploit this vulnerability to extract<br /> the passwords from the user database and/or the device configuration files<br /> to conduct further attacks.

Vulnerable products and versions

CPE From Up to
cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*