CVE-2020-10264
Severity CVSS v4.0:
Pending analysis
Type:
CWE-306
Missing Authentication for Critical Function
Publication date:
06/04/2020
Last modified:
14/09/2021
Description
CB3 SW Version 3.3 and upwards, e-series SW Version 5.0 and upwards allow authenticated access to the RTDE (Real-Time Data Exchange) interface on port 30004 which allows setting registers, the speed slider fraction as well as digital and analog Outputs. Additionally unautheticated reading of robot data is also possible
Impact
Base Score 3.x
8.80
Severity 3.x
HIGH
Base Score 2.0
5.80
Severity 2.0
MEDIUM
Vulnerable products and versions
| CPE | From | Up to |
|---|---|---|
| cpe:2.3:a:universal-robots:ur_software:*:*:*:*:*:*:*:* | 3.0.14989 (including) | 3.3.3.292 (including) |
| cpe:2.3:h:universal-robots:ur10:-:*:*:*:*:*:*:* | ||
| cpe:2.3:h:universal-robots:ur3:-:*:*:*:*:*:*:* | ||
| cpe:2.3:h:universal-robots:ur5:-:*:*:*:*:*:*:* | ||
| cpe:2.3:a:universal-robots:ur_software:*:*:*:*:*:*:*:* | 5.0 (including) | |
| cpe:2.3:h:universal-robots:ur10e:-:*:*:*:*:*:*:* | ||
| cpe:2.3:h:universal-robots:ur3e:-:*:*:*:*:*:*:* | ||
| cpe:2.3:h:universal-robots:ur5e:-:*:*:*:*:*:*:* |
To consult the complete list of CPE names with products and versions, see this page