CVE-2020-16100

Severity CVSS v4.0:
Pending analysis
Type:
CWE-404 Improper Resource Shutdown or Release
Publication date:
15/09/2020
Last modified:
24/09/2020

Description

It is possible for an unauthenticated remote DCOM websocket connection to crash the Command Centre service's DCOM websocket thread due to improper shutdown of closed websocket connections, preventing it from accepting future DCOM websocket (Configuration Client) connections. Affected versions are v8.20 prior to v8.20.1166(MR3), v8.10 prior to v8.10.1211(MR5), v8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier.

Vulnerable products and versions

CPE From Up to
cpe:2.3:a:gallagher:command_centre:*:*:*:*:*:*:*:* 8.00 (including) 8.00.1228 (excluding)
cpe:2.3:a:gallagher:command_centre:*:*:*:*:*:*:*:* 8.10 (including) 8.10.1211 (excluding)
cpe:2.3:a:gallagher:command_centre:*:*:*:*:*:*:*:* 8.20 (including) 8.20.1166 (excluding)
cpe:2.3:a:gallagher:command_centre:8.00.1228:-:*:*:*:*:*:*
cpe:2.3:a:gallagher:command_centre:8.10.1211:-:*:*:*:*:*:*
cpe:2.3:a:gallagher:command_centre:8.20.1166:-:*:*:*:*:*:*