CVE-2020-24054

Severity CVSS v4.0:
Pending analysis
Type:
CWE-78 OS Command Injections
Publication date:
21/08/2020
Last modified:
27/08/2020

Description

The administration console of the Moog EXO Series EXVF5C-2 and EXVP7C2-3 units features a 'statusbroadcast' command that can spawn a given process repeatedly at a certain time interval as 'root'. One of the limitations of this feature is that it only takes a path to a binary without arguments; however, this can be circumvented using special shell variables, such as '${IFS}'. As a result, an attacker can execute arbitrary commands as 'root' on the units.

Vulnerable products and versions

CPE From Up to
cpe:2.3:o:moog:exvf5c-2_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:moog:exvf5c-2:-:*:*:*:*:*:*:*
cpe:2.3:o:moog:exvp7c2-3_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:moog:exvp7c2-3:-:*:*:*:*:*:*:*