CVE-2021-36708

Severity CVSS v4.0:
Pending analysis
Type:
CWE-640 Weak Password Recovery Mechanism for Forgotten Password
Publication date:
06/08/2021
Last modified:
12/08/2021

Description

In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router.

Vulnerable products and versions

CPE From Up to
cpe:2.3:o:prolink:prc2402m_firmware:*:*:*:*:*:*:*:* 1.0.18 (including)
cpe:2.3:h:prolink:prc2402m:-:*:*:*:*:*:*:*