CVE-2023-29468

Severity CVSS v4.0:
Pending analysis
Type:
CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Publication date:
14/08/2023
Last modified:
05/05/2025

Description

The Texas Instruments (TI) WiLink WL18xx MCP driver does not limit the number of information elements (IEs) of type XCC_EXT_1_IE_ID or XCC_EXT_2_IE_ID that can be parsed in a management frame. Using a specially crafted frame, a buffer overflow can be triggered that can potentially lead to remote code execution. This affects WILINK8-WIFI-MCP8 version 8.5_SP3 and earlier.

Vulnerable products and versions

CPE From Up to
cpe:2.3:a:ti:wilink8-wifi-mcp8:*:*:*:*:*:*:*:* 8.5 (excluding)
cpe:2.3:a:ti:wilink8-wifi-mcp8:8.5:-:*:*:*:*:*:*
cpe:2.3:a:ti:wilink8-wifi-mcp8:8.5:sp3:*:*:*:*:*:*


References to Advisories, Solutions, and Tools