Description
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker to escalate privileges by editing the Legacy GRUB bootloader configuration to start a root shell upon boot of the host OS. This is called F06.
Impact
Base Score 3.x
7.20
Severity 3.x
HIGH
Vulnerable products and versions
| CPE | From | Up to |
|---|---|---|
| cpe:2.3:o:entrust:nshield_5c_firmware:*:*:*:*:*:*:*:* | 13.6.12 (excluding) | |
| cpe:2.3:o:entrust:nshield_5c_firmware:*:*:*:*:*:*:*:* | 13.7 (including) | 13.9.0 (excluding) |
| cpe:2.3:h:entrust:nshield_5c:-:*:*:*:*:*:*:* | ||
| cpe:2.3:o:entrust:nshield_hsmi_firmware:*:*:*:*:*:*:*:* | 13.6.12 (excluding) | |
| cpe:2.3:o:entrust:nshield_hsmi_firmware:*:*:*:*:*:*:*:* | 13.7 (including) | 13.9.0 (excluding) |
| cpe:2.3:h:entrust:nshield_hsmi:-:*:*:*:*:*:*:* | ||
| cpe:2.3:o:entrust:nshield_connect_xc_base_firmware:*:*:*:*:*:*:*:* | 13.6.12 (excluding) | |
| cpe:2.3:o:entrust:nshield_connect_xc_base_firmware:*:*:*:*:*:*:*:* | 13.7 (including) | 13.9.0 (excluding) |
| cpe:2.3:h:entrust:nshield_connect_xc_base:-:*:*:*:*:*:*:* | ||
| cpe:2.3:o:entrust:nshield_connect_xc_mid_firmware:*:*:*:*:*:*:*:* | 13.6.12 (excluding) | |
| cpe:2.3:o:entrust:nshield_connect_xc_mid_firmware:*:*:*:*:*:*:*:* | 13.7 (including) | 13.9.0 (excluding) |
| cpe:2.3:h:entrust:nshield_connect_xc_mid:-:*:*:*:*:*:*:* | ||
| cpe:2.3:o:entrust:nshield_connect_xc_high_firmware:*:*:*:*:*:*:*:* | 13.6.12 (excluding) | |
| cpe:2.3:o:entrust:nshield_connect_xc_high_firmware:*:*:*:*:*:*:*:* | 13.7 (including) | 13.9.0 (excluding) |
| cpe:2.3:h:entrust:nshield_connect_xc_high:-:*:*:*:*:*:*:* |
To consult the complete list of CPE names with products and versions, see this page