Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2020-4644

Publication date:
29/07/2020
IBM Planning Analytics Local 2.0.0 through 2.0.9.1 could allow a remote attacker to hijack the clicking action of the victim. By persuading a victim to visit a malicious Web site, a remote attacker could exploit this vulnerability to hijack the victim's click actions and possibly launch further attacks against the victim. IBM X-Force ID: 185716.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2020-4567

Publication date:
29/07/2020
IBM Tivoli Key Lifecycle Manager 3.0.1 and 4.0 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 184156.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2020-4572

Publication date:
29/07/2020
IBM Tivoli Key Lifecycle Manager 3.0.1 and 4.0 could allow a remote attacker to obtain sensitive information when a detailed technical error message is returned in the browser. This information could be used in further attacks against the system. IBM X-Force ID: 184179.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2020-4573

Publication date:
29/07/2020
IBM Tivoli Key Lifecycle Manager 3.0.1 and 4.0 could disclose sensitive information due to responding to unauthenticated HTTP requests. IBM X-Force ID: 184180.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2020-4569

Publication date:
29/07/2020
IBM Tivoli Key Lifecycle Manager 3.0.1 and 4.0 uses a protection mechanism that relies on the existence or values of an input, but the input can be modified by an untrusted actor in a way that bypasses the protection mechanism. IBM X-Force ID: 184158.
Severity CVSS v4.0: Pending analysis
Last modification:
12/07/2022

CVE-2020-14486

Publication date:
29/07/2020
An attacker may bypass permission/authorization checks in OpenClinic GA 5.09.02 and 5.89.05b by ignoring the redirect of a permission failure, which may allow unauthorized execution of commands.
Severity CVSS v4.0: Pending analysis
Last modification:
29/07/2020

CVE-2020-14487

Publication date:
29/07/2020
OpenClinic GA 5.09.02 contains a hidden default user account that may be accessed if an administrator has not expressly turned off this account, which may allow an attacker to login and execute arbitrary commands.
Severity CVSS v4.0: Pending analysis
Last modification:
29/07/2020

CVE-2020-14488

Publication date:
29/07/2020
OpenClinic GA 5.09.02 and 5.89.05b does not properly verify uploaded files, which may allow a low-privilege user to upload and execute arbitrary files on the system.
Severity CVSS v4.0: Pending analysis
Last modification:
29/07/2020

CVE-2020-2078

Publication date:
29/07/2020
Passwords are stored in plain text within the configuration of SICK Package Analytics software up to and including V04.1.1. An authorized attacker could access these stored plaintext credentials and gain access to the ftp service. Storing a password in plaintext allows attackers to easily gain access to systems, potentially compromising personal information or other sensitive information.
Severity CVSS v4.0: Pending analysis
Last modification:
03/08/2020

CVE-2020-2077

Publication date:
29/07/2020
SICK Package Analytics software up to and including version V04.0.0 are vulnerable due to incorrect default permissions settings. An unauthorized attacker could read sensitive data from the system by querying for known files using the REST API directly.
Severity CVSS v4.0: Pending analysis
Last modification:
03/08/2020

CVE-2020-2076

Publication date:
29/07/2020
SICK Package Analytics software up to and including version V04.0.0 are vulnerable to an authentication bypass by directly interfacing with the REST API. An attacker can send unauthorized requests, bypass current authentication controls presented by the application and could potentially write files without authentication.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2020-9691

Publication date:
29/07/2020
Magento versions 2.3.5-p1 and earlier, and 2.3.5-p1 and earlier have a dom-based cross-site scripting vulnerability. Successful exploitation could lead to arbitrary code execution.
Severity CVSS v4.0: Pending analysis
Last modification:
29/07/2020