Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2017-18506

Publication date:
12/08/2019
The woocommerce-pdf-invoices-packing-slips plugin before 2.0.13 for WordPress has XSS via the tab or section variable on settings screens.
Severity CVSS v4.0: Pending analysis
Last modification:
16/08/2019

CVE-2019-14932

Publication date:
12/08/2019
The Recruitment module in Humanica Humatrix 7 1.0.0.681 and 1.0.0.203 allows remote attackers to access all candidates' information on the website via a modified selApp variable to personalData/resumeDetail.cfm. This includes personal information and other sensitive data.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2019-14940

Publication date:
12/08/2019
In Storage Performance Development Kit (SPDK) before 19.07, a user of a vhost can cause a crash if the target is sent invalid input.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-14939

Publication date:
12/08/2019
An issue was discovered in the mysql (aka mysqljs) module 2.17.1 for Node.js. The LOAD DATA LOCAL INFILE option is open by default.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2019-14935

Publication date:
12/08/2019
3CX Phone 15 on Windows has insecure permissions on the "%PROGRAMDATA%\3CXPhone for Windows\PhoneApp" installation directory, allowing Full Control access for Everyone, and leading to privilege escalation because of a StartUp link.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-14934

Publication date:
11/08/2019
An issue was discovered in PDFResurrect before 0.18. pdf_load_pages_kids in pdf.c doesn't validate a certain size value, which leads to a malloc failure and out-of-bounds write.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2019-14933

Publication date:
11/08/2019
Bagisto 0.1.5 allows CSRF under /admin URIs.
Severity CVSS v4.0: Pending analysis
Last modification:
14/08/2019

CVE-2019-14924

Publication date:
10/08/2019
An issue was discovered in GCDWebServer before 3.5.3. The method moveItem in the GCDWebUploader class checks the FileExtension of newAbsolutePath but not oldAbsolutePath. By leveraging this vulnerability, an adversary can make an inaccessible file be available (the credential of the app, for instance).
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2019-14355

Publication date:
10/08/2019
On ShapeShift KeepKey devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover secret data shown on the display. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. NOTE: the vendor's position is that there is "insignificant risk.
Severity CVSS v4.0: Pending analysis
Last modification:
05/08/2024

CVE-2019-14357

Publication date:
10/08/2019
On Mooltipass Mini devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. NOTE: the vendor's position is that an attack is not "realistically implementable.
Severity CVSS v4.0: Pending analysis
Last modification:
05/08/2024

CVE-2019-14354

Publication date:
10/08/2019
On Ledger Nano S and Nano X devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2019-12260

Publication date:
09/08/2019
Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option.
Severity CVSS v4.0: Pending analysis
Last modification: