Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2025-40758

Publication date:
14/08/2025
A vulnerability has been identified in Mendix SAML (Mendix 10.12 compatible) (All versions
Severity CVSS v4.0: Pending analysis
Last modification:
15/08/2025

CVE-2025-43983

Publication date:
14/08/2025
KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages.
Severity CVSS v4.0: Pending analysis
Last modification:
15/08/2025

CVE-2025-38745

Publication date:
14/08/2025
Dell OpenManage Enterprise, versions 3.10, 4.0, 4.1, and 4.2, contains an Insertion of Sensitive Information into Log File vulnerability in the Backup and Restore. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure.
Severity CVSS v4.0: Pending analysis
Last modification:
19/08/2025

CVE-2025-27847

Publication date:
14/08/2025
In ESPEC North America Web Controller 3 before 3.3.8, /api/v4/auth/ users session privileges are not revoked on logout.
Severity CVSS v4.0: Pending analysis
Last modification:
15/08/2025

CVE-2025-36612

Publication date:
14/08/2025
SupportAssist for Business PCs, version(s) 4.5.3 and prior, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to elevation of privileges.
Severity CVSS v4.0: Pending analysis
Last modification:
18/08/2025

CVE-2025-36613

Publication date:
14/08/2025
SupportAssist for Home PCs versions 4.6.3 and prior and SupportAssist for Business PCs versions 4.5.3 and prior, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access.
Severity CVSS v4.0: Pending analysis
Last modification:
18/08/2025

CVE-2025-38738

Publication date:
14/08/2025
SupportAssist for Home PCs Installer exe version(s) 4.8.2.29006 and prior, contain(s) an Incorrect Privilege Assignment vulnerability in the Installer. A low privileged attacker with local access could potentially exploit this vulnerability, leading to elevation of privileges.
Severity CVSS v4.0: Pending analysis
Last modification:
18/08/2025

CVE-2025-26484

Publication date:
14/08/2025
Dell CloudLink, versions 8.0 through 8.1.1, contains an Improper Restriction of XML External Entity Reference vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
Severity CVSS v4.0: Pending analysis
Last modification:
18/08/2025

CVE-2025-27845

Publication date:
14/08/2025
In ESPEC North America Web Controller 3 before 3.3.4, /api/v4/auth/ with any invalid authentication request results in exposing a JWT secret. This allows for elevated permissions to the UI.
Severity CVSS v4.0: Pending analysis
Last modification:
15/08/2025

CVE-2025-27846

Publication date:
14/08/2025
In ESPEC North America Web Controller 3 before 3.3.8, an attacker with physical access can gain elevated privileges because GRUB and the BIOS are unprotected.
Severity CVSS v4.0: Pending analysis
Last modification:
15/08/2025

CVE-2025-9036

Publication date:
14/08/2025
A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcasted over a WebSocket and can be intercepted by any local client listening on the connection.
Severity CVSS v4.0: HIGH
Last modification:
15/08/2025

CVE-2025-7353

Publication date:
14/08/2025
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
Severity CVSS v4.0: CRITICAL
Last modification: