Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2026-10717

Publication date:
02/06/2026
Out of bounds write and reads in openSeaChest’s --showSCSIDefects in Seagate’s openSeaChest v25.05.3 on all supported platforms allows for writing defect information out of bounds for very large defects lists via a very bad drive with lots of defects or a maliciously crafted SCSI device’s defect response length.
Severity CVSS v4.0: LOW
Last modification:
22/07/2026

CVE-2026-8936

Publication date:
02/06/2026
Fixed a VM panic caused by unbounded recursion in the grpcfuse kernel module when a container created deeply nested directories on a bind-mounted host folder and triggered a dentry invalidation event. This issue has been fixed in Docker Desktop 4.76.0.
Severity CVSS v4.0: HIGH
Last modification:
22/07/2026

CVE-2026-42029

Publication date:
02/06/2026
Rejected reason: This CVE is a duplicate of another CVE.
Severity CVSS v4.0: Pending analysis
Last modification:
02/06/2026

CVE-2026-10650

Publication date:
02/06/2026
A flaw has been found in warmcat libwebsockets up to 4.5.8. This issue affects the function lws_ssh_parse_plaintext of the file plugins/protocol_lws_ssh_base/sshd.c of the component SSH Protocol Handler. Executing a manipulation of the argument msg_len can lead to resource consumption. The attack may be launched remotely. The exploit has been published and may be used. This patch is called 3f9f0c6ecaf0e6f3f219d30632c5d1f2479d7498. A patch should be applied to remediate this issue.
Severity CVSS v4.0: MEDIUM
Last modification:
22/07/2026

CVE-2026-10661

Publication date:
02/06/2026
A vulnerability has been found in ahujasid blender-mcp up to 7636d13bded82eca58eb93c3f4cd8708dfdfbe8b. Impacted is the function Open of the file src/blender_mcp/server.py. The manipulation of the argument input_image_url leads to injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used. This product follows a rolling release approach for continuous delivery, so version details for affected or updated releases are not provided. The identifier of the patch is 5b37be25242e73dc4cf1328974d30458b9e5d67e. To fix this issue, it is recommended to deploy a patch.
Severity CVSS v4.0: LOW
Last modification:
22/07/2026

CVE-2026-35212

Publication date:
02/06/2026
OpenCTI is an open source platform for managing cyber threat intelligence knowledge and observables. Versions prior to 7.260227.0 are vulnerable to XSS in the rendering of email-message observable body data. The content of the body field isn't appropriately sanitized when being rendered. Does require user interaction but could be exploited by someone sharing stix or any of the ingester. This could lead to CSRF and then large scale session theft. Version 7.260227.0 contains a fix.
Severity CVSS v4.0: MEDIUM
Last modification:
22/07/2026

CVE-2021-4481

Publication date:
02/06/2026
Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges. Attackers can replace binaries or loaded modules on the host system to execute code with NT SYSTEM privileges.
Severity CVSS v4.0: HIGH
Last modification:
22/07/2026

CVE-2022-4992

Publication date:
02/06/2026
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service conditions. Attackers can compromise network communications to modify device settings such as alarm states or alarm limits, or overwhelm the system with excessive network traffic causing the Cockpit or M540 to reboot and lose network functionality.
Severity CVSS v4.0: HIGH
Last modification:
22/07/2026

CVE-2024-14036

Publication date:
02/06/2026
Dräger Core 1.0.5 and Dräger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the hospital network can send malformed SDC packets to exhaust CPU resources in the affected process, causing further SDC messages to no longer be processed.
Severity CVSS v4.0: HIGH
Last modification:
22/07/2026

CVE-2025-15653

Publication date:
02/06/2026
Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations contain a local security vulnerability that allows unauthorized individuals with physical access to compromise software integrity via USB interface manipulation. Attackers can exploit the unprotected USB interfaces to impair therapy functions, manipulate device-processed data, or leverage the device as a pivot point for broader network-based attacks when connected to a network or Dräger Service Connect.
Severity CVSS v4.0: HIGH
Last modification:
22/07/2026

CVE-2021-4480

Publication date:
02/06/2026
Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges. Attackers can replace binaries or loaded modules on the host system to execute code with NT SYSTEM privileges.
Severity CVSS v4.0: HIGH
Last modification:
22/07/2026

CVE-2026-49143

Publication date:
02/06/2026
BrowserStack Runner through 0.9.5 contains a remote code execution vulnerability in the /_log HTTP handler that allows unauthenticated network-adjacent attackers to execute arbitrary code by submitting crafted JSON request bodies to the handler, which passes user-supplied data to vm.runInNewContext() combined with eval(). Attackers can escape the Node.js vm sandbox by leveraging a host-context Function reference through util.format to access the host process via this.constructor.constructor, achieving full remote code execution on the underlying system without any authentication.
Severity CVSS v4.0: HIGH
Last modification:
22/07/2026