Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2020-1629

Publication date:
08/04/2020
A race condition vulnerability on Juniper Network Junos OS devices may cause the routing protocol daemon (RPD) process to crash and restart while processing a BGP NOTIFICATION message. This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.2 version 17.2R2 and later versions; 17.2X75 versions prior to 17.2X75-D105, 17.2X75-D110; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S7, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3-S3; 18.2X75 versions prior to 18.2X75-D410, 18.2X75-D420, 18.2X75-D50, 18.2X75-D60; 18.3 versions prior to 18.3R1-S5, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R2-S2, 18.4R3; 19.1 versions prior to 19.1R1-S2, 19.1R2; 19.2 versions prior to 19.2R1-S4, 19.2R2. This issue does not affect Juniper Networks Junos OS prior to version 16.1R1.
Severity CVSS v4.0: Pending analysis
Last modification:
25/04/2022

CVE-2020-1630

Publication date:
08/04/2020
A privilege escalation vulnerability in Juniper Networks Junos OS devices configured with dual Routing Engines (RE), Virtual Chassis (VC) or high-availability cluster may allow a local authenticated low-privileged user with access to the shell to perform unauthorized configuration modification. This issue does not affect Junos OS device with single RE or stand-alone configuration. This issue affects Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S14; 12.3X48 versions prior to 12.3X48-D86, 12.3X48-D90; 14.1X53 versions prior to 14.1X53-D51; 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D181, 15.1X49-D190; 15.1X53 versions prior to 15.1X53-D592; 16.1 versions prior to 16.1R4-S13, 16.1R7-S6; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S6, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3-S1; 18.2 versions prior to 18.2X75-D12, 18.2X75-D33, 18.2X75-D420, 18.2X75-D60, 18.2X75-D411; 18.3 versions prior to 18.3R1-S5, 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R1-S4, 18.4R2-S1, 18.4R3; 19.1 versions prior to 19.1R1-S2, 19.1R2; 19.2 versions prior to 19.2R1-S1, 19.2R2.
Severity CVSS v4.0: Pending analysis
Last modification:
22/11/2021

CVE-2020-1639

Publication date:
08/04/2020
When an attacker sends a specific crafted Ethernet Operation, Administration, and Maintenance (Ethernet OAM) packet to a target device, it may improperly handle the incoming malformed data and fail to sanitize this incoming data resulting in an overflow condition. This overflow condition in Juniper Networks Junos OS allows an attacker to cause a Denial of Service (DoS) condition by coring the CFM daemon. Continued receipt of these packets may cause an extended Denial of Service condition. This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95 on SRX Series; 14.1X50 versions prior to 14.1X50-D145; 14.1X53 versions prior to 14.1X53-D47; 15.1 versions prior to 15.1R2; 15.1X49 versions prior to 15.1X49-D170 on SRX Series; 15.1X53 versions prior to 15.1X53-D67.
Severity CVSS v4.0: Pending analysis
Last modification:
21/10/2022

CVE-2020-1638

Publication date:
08/04/2020
The FPC (Flexible PIC Concentrator) of Juniper Networks Junos OS and Junos OS Evolved may restart after processing a specific IPv4 packet. Only packets destined to the device itself, successfully reaching the RE through existing edge and control plane filtering, will be able to cause the FPC restart. When this issue occurs, all traffic via the FPC will be dropped. By continuously sending this specific IPv4 packet, an attacker can repeatedly crash the FPC, causing an extended Denial of Service (DoS) condition. This issue can only occur when processing a specific IPv4 packet. IPv6 packets cannot trigger this issue. This issue affects: Juniper Networks Junos OS on MX Series with MPC10E or MPC11E and PTX10001: 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. Juniper Networks Junos OS Evolved on on QFX5220, and PTX10003 series: 19.2-EVO versions; 19.3-EVO versions; 19.4-EVO versions prior to 19.4R2-EVO. This issue does not affect Junos OS versions prior to 19.2R1. This issue does not affect Junos OS Evolved versions prior to 19.2R1-EVO.
Severity CVSS v4.0: Pending analysis
Last modification:
01/01/2022

CVE-2020-8826

Publication date:
08/04/2020
As of v1.5.0, the Argo web interface authentication system issued immutable tokens. Authentication tokens, once issued, were usable forever without expiration—there was no refresh or forced re-authentication.
Severity CVSS v4.0: Pending analysis
Last modification:
07/08/2024

CVE-2020-8827

Publication date:
08/04/2020
As of v1.5.0, the Argo API does not implement anti-automation measures such as rate limiting, account lockouts, or other anti-bruteforce measures. Attackers can submit an unlimited number of authentication attempts without consequence.
Severity CVSS v4.0: Pending analysis
Last modification:
07/08/2024

CVE-2020-8828

Publication date:
08/04/2020
As of v1.5.0, the default admin password is set to the argocd-server pod name. For insiders with access to the cluster or logs, this issue could be abused for privilege escalation, as Argo has privileged roles. A malicious insider is the most realistic threat, but pod names are not meant to be kept secret and could wind up just about anywhere.
Severity CVSS v4.0: Pending analysis
Last modification:
07/08/2024

CVE-2020-1885

Publication date:
08/04/2020
Writing to an unprivileged file from a privileged OVRRedir.exe process in Oculus Desktop before 1.44.0.32849 on Windows allows local users to write to arbitrary files and consequently gain privileges via vectors involving a hard link to a log file.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2020-1613

Publication date:
08/04/2020
A vulnerability in the BGP FlowSpec implementation may cause a Juniper Networks Junos OS device to terminate an established BGP session upon receiving a specific BGP FlowSpec advertisement. The BGP NOTIFICATION message that terminates an established BGP session is sent toward the peer device that originally sent the specific BGP FlowSpec advertisement. This specific BGP FlowSpec advertisement received from a BGP peer might get propagated from a Junos OS device running the fixed release to another device that is vulnerable causing BGP session termination downstream. This issue affects IPv4 and IPv6 BGP FlowSpec deployment. This issue affects Juniper Networks Junos OS: 12.3; 12.3X48 on SRX Series; 14.1X53 on EX and QFX Series; 15.1 versions prior to 15.1R7-S5; 15.1F versions prior to 15.1F6-S13; 15.1X49 versions prior to 15.1X49-D180 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110; 15.1X53 versions prior to 15.1X53-D497 on NFX Series; 15.1X53 versions prior to 15.1X53-D592 on EX2300/EX3400; 16.1 versions prior to 16.1R7-S7; 17.1 versions prior to 17.1R2-S12, 17.1R3; 17.2 versions prior to 17.2R2-S7, 17.2R3; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110, 17.2X75-D44; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R1-S8, 17.4R2; 18.1 versions prior to 18.1R2-S4, 18.1R3; 18.2X75 versions prior to 18.2X75-D20.
Severity CVSS v4.0: Pending analysis
Last modification:
18/11/2021

CVE-2020-1625

Publication date:
08/04/2020
The kernel memory usage represented as "temp" via 'show system virtual-memory' may constantly increase when Integrated Routing and Bridging (IRB) is configured with multiple underlay physical interfaces, and one interface flaps. This memory leak can affect running daemons (processes), leading to an extended Denial of Service (DoS) condition. Usage of "temp" virtual memory, shown here by a constantly increasing value of outstanding Requests, can be monitored by executing the 'show system virtual-memory' command as shown below: user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 10551 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6460 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 16101 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6665 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 user@junos> show system virtual-memory |match "fpc|type|temp" fpc0: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2023 431K - 21867 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 fpc1: -------------------------------------------------------------------------- Type InUse MemUse HighUse Requests Size(s) temp 2020 431K - 6858 16,32,64,128,256,512,1024,2048,4096,65536,262144,1048576,2097152,4194304,8388608 This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S6; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R2-S8, 17.2R3-S3; 17.2X75 versions prior to 17.2X75-D44; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S5, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3; 18.2X75 versions prior to 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D60; 18.3 versions prior to 18.3R1-S5, 18.3R2-S3, 18.3R3; 18.4 versions prior to 18.4R2-S2, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S3, 19.2R2. This issue does not affect Juniper Networks Junos OS 12.3 and 15.1.
Severity CVSS v4.0: Pending analysis
Last modification:
14/09/2021

CVE-2020-1626

Publication date:
08/04/2020
A vulnerability in Juniper Networks Junos OS Evolved may allow an attacker to cause a Denial of Service (DoS) by sending a high rate of specific packets to the device, resulting in a pfemand process crash. The pfemand process is responsible for packet forwarding on the device. By continuously sending the packet flood, an attacker can repeatedly crash the pfemand process causing a sustained Denial of Service. This issue can only be triggered by traffic sent to the device. Transit traffic does not cause this issue. This issue affects all version of Junos OS Evolved prior to 19.1R1-EVO.
Severity CVSS v4.0: Pending analysis
Last modification:
21/07/2021

CVE-2020-1618

Publication date:
08/04/2020
On Juniper Networks EX and QFX Series, an authentication bypass vulnerability may allow a user connected to the console port to login as root without any password. This issue might only occur in certain scenarios: • At the first reboot after performing device factory reset using the command “request system zeroize”; or • A temporary moment during the first reboot after the software upgrade when the device configured in Virtual Chassis mode. This issue affects Juniper Networks Junos OS on EX and QFX Series: 14.1X53 versions prior to 14.1X53-D53; 15.1 versions prior to 15.1R7-S4; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S4; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2; 18.3 versions prior to 18.3R1-S7, 18.3R2. This issue does not affect Juniper Networks Junos OS 12.3.
Severity CVSS v4.0: Pending analysis
Last modification:
22/11/2021