Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2019-10061

Publication date:
26/03/2019
utils/find-opencv.js in node-opencv (aka OpenCV bindings for Node.js) prior to 6.1.0 is vulnerable to Command Injection. It does not validate user input allowing attackers to execute arbitrary commands.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-7711

Publication date:
26/03/2019
An issue was discovered in the Interpeak IPCOMShell TELNET server on Green Hills INTEGRITY RTOS 5.0.4. The undocumented shell command "prompt" sets the (user controlled) shell's prompt value, which is used as a format string input to printf, resulting in an information leak of memory addresses.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-7712

Publication date:
26/03/2019
An issue was discovered in handler_ipcom_shell_pwd in the Interpeak IPCOMShell TELNET server on Green Hills INTEGRITY RTOS 5.0.4. When using the pwd command, the current working directory path is used as the first argument to printf() without a proper check. An attacker may thus forge a path containing format string modifiers to get a custom format string evaluated. This results in an information leak of memory addresses.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-7713

Publication date:
26/03/2019
An issue was discovered in the Interpeak IPCOMShell TELNET server on Green Hills INTEGRITY RTOS 5.0.4. There is a heap-based buffer overflow in the function responsible for printing the shell prompt, when a custom modifier is used to display information such as a process ID, IP address, or current working directory. Modifier expansion triggers this overflow, causing memory corruption or a crash (and also leaks memory address information).
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-7714

Publication date:
26/03/2019
An issue was discovered in Interpeak IPWEBS on Green Hills INTEGRITY RTOS 5.0.4. It allocates 60 bytes for the HTTP Authentication header. However, when copying this header to parse, it does not check the size of the header, leading to a stack-based buffer overflow.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-10060

Publication date:
26/03/2019
The Verix Multi-app Conductor application 2.7 for Verifone Verix suffers from a buffer overflow vulnerability that allows attackers to execute arbitrary code via a long configuration key value. An attacker must be able to download files to the device in order to exploit this vulnerability.
Severity CVSS v4.0: Pending analysis
Last modification:
28/03/2019

CVE-2017-7342

Publication date:
25/03/2019
A weak password recovery process vulnerability in Fortinet FortiPortal versions 4.0.0 and below allows an attacker to execute unauthorized code or commands via a hidden Close button
Severity CVSS v4.0: Pending analysis
Last modification:
26/03/2019

CVE-2019-7642

Publication date:
25/03/2019
D-Link routers with the mydlink feature have some web interfaces without authentication requirements. An attacker can remotely obtain users' DNS query logs and login logs. Vulnerable targets include but are not limited to the latest firmware versions of DIR-817LW (A1-1.04), DIR-816L (B1-2.06), DIR-816 (B1-2.06?), DIR-850L (A1-1.09), and DIR-868L (A1-1.10).
Severity CVSS v4.0: Pending analysis
Last modification:
23/04/2021

CVE-2019-0204

Publication date:
25/03/2019
A specifically crafted Docker image running under the root user can overwrite the init helper binary of the container runtime and/or the command executor in Apache Mesos versions pre-1.4.x, 1.4.0 to 1.4.2, 1.5.0 to 1.5.2, 1.6.0 to 1.6.1, and 1.7.0 to 1.7.1. A malicious actor can therefore gain root-level code execution on the host.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2019-6538

Publication date:
25/03/2019
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
Severity CVSS v4.0: Pending analysis
Last modification:
22/05/2025

CVE-2018-15583

Publication date:
25/03/2019
Cross-Site Scripting (XSS) vulnerability in point_list.php in GNUBOARD5 before 5.3.1.6 allows remote attackers to inject arbitrary web script or HTML via the popup title parameter.
Severity CVSS v4.0: Pending analysis
Last modification:
19/09/2024

CVE-2017-7340

Publication date:
25/03/2019
A Cross-Site Scripting vulnerability in Fortinet FortiPortal versions 4.0.0 and below allows an attacker to execute unauthorized code or commands via the applicationSearch parameter in the FortiView functionality.
Severity CVSS v4.0: Pending analysis
Last modification:
26/03/2019