Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2016-8374

Publication date:
13/02/2017
An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-9343

Publication date:
13/02/2017
An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-8372

Publication date:
13/02/2017
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-8379

Publication date:
13/02/2017
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-9339

Publication date:
13/02/2017
An issue was discovered in INTERSCHALT Maritime Systems VDR G4e Versions 5.220 and prior. External input is used to construct paths to files and directories without properly neutralizing special elements within the pathname that could allow an attacker to read files on the system, a Path Traversal.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-8368

Publication date:
13/02/2017
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-8370

Publication date:
13/02/2017
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-8566

Publication date:
13/02/2017
An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-8567

Publication date:
13/02/2017
An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-5801

Publication date:
13/02/2017
An issue was discovered in OmniMetrix OmniView, Version 1.2. Insufficient password requirements for the OmniView web application may allow an attacker to gain access by brute forcing account passwords.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-5782

Publication date:
13/02/2017
An issue was discovered in Locus Energy LGate prior to 1.05H, LGate 50, LGate 100, LGate 101, LGate 120, and LGate 320. Locus Energy meters use a PHP script to manage the energy meter parameters for voltage monitoring and network configuration. The PHP code does not properly validate information that is sent in the POST request.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026

CVE-2016-5802

Publication date:
13/02/2017
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to 2.10.10. Multiple instances of out-of-bounds write conditions may allow malicious files to be read and executed by the affected software.
Severity CVSS v4.0: Pending analysis
Last modification:
13/05/2026