Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2013-0677

Publication date:
21/03/2013
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-0679

Publication date:
21/03/2013
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-0665

Publication date:
21/03/2013
Schweitzer Engineering Laboratories (SEL) AcSELerator QuickSet before 5.12.0.1 uses weak permissions for its Program Files directory, which allows local users to replace executable files, and consequently gain privileges, via standard filesystem operations.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-0668

Publication date:
21/03/2013
Multiple cross-site scripting (XSS) vulnerabilities in the HMI web application in Siemens WinCC (TIA Portal) 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-0669

Publication date:
21/03/2013
The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-0670

Publication date:
21/03/2013
CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-0671

Publication date:
21/03/2013
Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-0672

Publication date:
21/03/2013
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-0667

Publication date:
21/03/2013
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2011-4515

Publication date:
21/03/2013
Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-2616

Publication date:
20/03/2013
lib/mini_magick.rb in the MiniMagick Gem 1.3.1 for Ruby allows remote attackers to execute arbitrary commands via shell metacharacters in a URL.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025

CVE-2013-2617

Publication date:
20/03/2013
lib/curl.rb in the Curl Gem for Ruby allows remote attackers to execute arbitrary commands via shell metacharacters in a URL.
Severity CVSS v4.0: Pending analysis
Last modification:
11/04/2025