Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2024-54015

Publication date:
11/02/2025
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions = V8.80 = V8.80 = V8.80
Severity CVSS v4.0: HIGH
Last modification:
15/04/2026

CVE-2024-54089

Publication date:
11/02/2025
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key.<br /> This could allow an attacker to guess or decrypt the password from the cyphertext.
Severity CVSS v4.0: HIGH
Last modification:
15/04/2026

CVE-2024-54090

Publication date:
11/02/2025
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function.<br /> This could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state.
Severity CVSS v4.0: MEDIUM
Last modification:
15/04/2026

CVE-2024-53648

Publication date:
11/02/2025
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions
Severity CVSS v4.0: HIGH
Last modification:
15/04/2026

CVE-2024-53651

Publication date:
11/02/2025
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device.
Severity CVSS v4.0: MEDIUM
Last modification:
15/04/2026

CVE-2024-45386

Publication date:
11/02/2025
A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions
Severity CVSS v4.0: HIGH
Last modification:
15/04/2026

CVE-2024-13506

Publication date:
11/02/2025
The GeoDirectory – WP Business Directory Plugin and Classified Listings Directory plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the display_name profile parameter in all versions up to, and including, 2.8.97 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with Subscriber-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
Severity CVSS v4.0: Pending analysis
Last modification:
15/04/2026

CVE-2024-23814

Publication date:
11/02/2025
The integrated ICMP service of the network stack of affected devices can be forced to exhaust its available memory resources when receiving specially crafted messages targeting IP fragment re-assembly. This could allow an unauthenticated remote attacker to cause a temporary denial of service condition of the ICMP service, other communication services are not affected. Affected devices will resume normal operation after the attack terminates.
Severity CVSS v4.0: MEDIUM
Last modification:
15/04/2026

CVE-2023-37482

Publication date:
11/02/2025
The login functionality of the web server in affected devices does not normalize the response times of login attempts. An unauthenticated remote attacker could exploit this side-channel information to distinguish between valid and invalid usernames.
Severity CVSS v4.0: MEDIUM
Last modification:
15/04/2026

CVE-2025-0525

Publication date:
11/02/2025
In affected versions of Octopus Server the preview import feature could be leveraged to identify the existence of a target file. This could provide an adversary with information that may aid in further attacks against the server.
Severity CVSS v4.0: LOW
Last modification:
02/07/2025

CVE-2025-26408

Publication date:
11/02/2025
The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device&amp;#39;s firmware. All known versions are affected.
Severity CVSS v4.0: Pending analysis
Last modification:
15/04/2026

CVE-2025-26409

Publication date:
11/02/2025
A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP &gt;= 6.4.1.
Severity CVSS v4.0: Pending analysis
Last modification:
15/04/2026