Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2019-11895

Publication date:
29/05/2019
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
Severity CVSS v4.0: Pending analysis
Last modification:
06/10/2020

CVE-2019-11896

Publication date:
29/05/2019
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.
Severity CVSS v4.0: Pending analysis
Last modification:
06/10/2020

CVE-2018-13365

Publication date:
29/05/2019
An Information Exposure vulnerability in Fortinet FortiOS 6.0.1, 5.6.5 and below, allow attackers to learn private IP as well as the hostname of FortiGate via Application Control Block page.
Severity CVSS v4.0: Pending analysis
Last modification:
30/05/2019

CVE-2019-11891

Publication date:
29/05/2019
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
Severity CVSS v4.0: Pending analysis
Last modification:
06/10/2020

CVE-2019-11892

Publication date:
29/05/2019
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
Severity CVSS v4.0: Pending analysis
Last modification:
06/10/2020

CVE-2019-11893

Publication date:
29/05/2019
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction.
Severity CVSS v4.0: Pending analysis
Last modification:
06/10/2020

CVE-2019-6321

Publication date:
29/05/2019
HP has identified a security vulnerability with some versions of Workstation BIOS (UEFI Firmware) where the runtime BIOS code could be tampered with if the TPM is disabled. This vulnerability relates to Workstations whose TPM is disabled by default.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-6322

Publication date:
29/05/2019
HP has identified a security vulnerability with some versions of Workstation BIOS (UEFI Firmware) where the runtime BIOS code could be tampered with if the TPM is disabled. This vulnerability relates to Workstations whose TPM is enabled by default.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-11872

Publication date:
29/05/2019
The Hustle (aka wordpress-popup) plugin 6.0.7 for WordPress is vulnerable to CSV Injection as it allows for injecting malicious code into a pop-up window. Successful exploitation grants an attacker with a right to execute malicious code on the administrator's computer through Excel functions as the plugin does not sanitize the user's input and allows insertion of any text.
Severity CVSS v4.0: Pending analysis
Last modification:
24/02/2023

CVE-2019-12452

Publication date:
29/05/2019
types/types.go in Containous Traefik 1.7.x through 1.7.11, when the --api flag is used and the API is publicly reachable and exposed without sufficient access control (which is contrary to the API documentation), allows remote authenticated users to discover password hashes by reading the Basic HTTP Authentication or Digest HTTP Authentication section, or discover a key by reading the ClientTLS section. These can be found in the JSON response to a /api request.
Severity CVSS v4.0: Pending analysis
Last modification:
28/07/2021

CVE-2019-6958

Publication date:
29/05/2019
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
Severity CVSS v4.0: Pending analysis
Last modification:
31/01/2023

CVE-2019-12347

Publication date:
29/05/2019
In pfSense 2.4.4-p3, a stored XSS vulnerability occurs when attackers inject a payload into the Name or Description field via an acme_accountkeys_edit.php action. The vulnerability occurs due to input validation errors.
Severity CVSS v4.0: Pending analysis
Last modification:
30/05/2019