Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2018-8872

Publication date:
04/05/2018
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-7522

Publication date:
04/05/2018
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-8853

Publication date:
04/05/2018
Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Also, attackers may gain access to unauthorized resources from the underlying Windows operating system.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-8857

Publication date:
04/05/2018
Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-8861

Publication date:
04/05/2018
Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized attacker to break-out from the containment of the kiosk environment, attain elevated privileges from the underlying Windows OS, and access unauthorized resources from the operating system.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-8865

Publication date:
04/05/2018
In Lantech IDS 2102 2.0 and prior, a stack-based buffer overflow vulnerability has been identified which may allow remote code execution. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Severity CVSS v4.0: Pending analysis
Last modification:
29/09/2020

CVE-2018-10726

Publication date:
04/05/2018
A stored XSS vulnerability was found in Datenstrom Yellow 0.7.3 via an "Edit page" action. NOTE: the vendor disputes the relevance of this report because an installation accessible to untrusted users is supposed to have parserSafeMode=1 in system/config/config.ini to prevent XSS
Severity CVSS v4.0: Pending analysis
Last modification:
05/08/2024

CVE-2017-7176

Publication date:
04/05/2018
Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2017-1743

Publication date:
04/05/2018
IBM WebSphere Application Server 7.0, 8.0, 8.5, and 9.0 could allow a remote attacker to obtain sensitive information caused by improper handling of Administrative Console panel fields. When exploited an attacker could browse the file system. IBM X-Force ID: 134933.
Severity CVSS v4.0: Pending analysis
Last modification:
06/06/2018

CVE-2018-10641

Publication date:
04/05/2018
D-Link DIR-601 A1 1.02NA devices do not require the old password for a password change, which occurs in cleartext.
Severity CVSS v4.0: Pending analysis
Last modification:
26/04/2023

CVE-2018-10562

Publication date:
04/05/2018
An issue was discovered on Dasan GPON home routers. Command Injection can occur via the dest_host parameter in a diag_action=ping request to a GponForm/diag_Form URI. Because the router saves ping results in /tmp and transmits them to the user when the user revisits /diag.html, it's quite simple to execute commands and retrieve their output.
Severity CVSS v4.0: Pending analysis
Last modification:
05/11/2025

CVE-2018-10561

Publication date:
04/05/2018
An issue was discovered on Dasan GPON home routers. It is possible to bypass authentication simply by appending "?images" to any URL of the device that requires authentication, as demonstrated by the /menu.html?images/ or /GponForm/diag_FORM?images/ URI. One can then manage the device.
Severity CVSS v4.0: Pending analysis
Last modification:
05/11/2025