CVE-2009-3977
Severity CVSS v4.0:
Pending analysis
Type:
CWE-119
Buffer Errors
Publication date:
19/11/2009
Last modified:
09/04/2025
Description
Multiple buffer overflows in a certain ActiveX control in ActiveDom.ocx in HP OpenView Network Node Manager (OV NNM) 7.53 might allow remote attackers to cause a denial of service (memory corruption) or have unspecified other impact via a long string argument to the (1) DisplayName, (2) AddGroup, (3) InstallComponent, or (4) Subscribe method. NOTE: this issue is not a vulnerability in many environments, because the control is not marked as safe for scripting and would not execute with default Internet Explorer settings.
Impact
Base Score 2.0
5.00
Severity 2.0
MEDIUM
Vulnerable products and versions
| CPE | From | Up to |
|---|---|---|
| cpe:2.3:a:hp:openview_network_node_manager:7.53:*:*:*:*:*:*:* |
To consult the complete list of CPE names with products and versions, see this page
References to Advisories, Solutions, and Tools
- http://seclists.org/fulldisclosure/2009/Nov/199
- http://www.coresecurity.com/content/openview_nnm_internaldb_dos
- https://exchange.xforce.ibmcloud.com/vulnerabilities/54377
- http://seclists.org/fulldisclosure/2009/Nov/199
- http://www.coresecurity.com/content/openview_nnm_internaldb_dos
- https://exchange.xforce.ibmcloud.com/vulnerabilities/54377