CVE-2013-0651

Severity CVSS v4.0:
Pending analysis
Type:
CWE-264 Permissions, Privileges, and Access Control
Publication date:
27/01/2013
Last modified:
11/04/2025

Description

The Portal installation process in GE Intelligent Platforms Proficy Real-Time Information Portal stores sensitive information under the web root with insufficient access control, which allows remote attackers to read configuration files, and discover data-source credentials, via a direct request.

Vulnerable products and versions

CPE From Up to
cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:-:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:2.6:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.0:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.0:sp1:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.5:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.5:sp1:*:*:*:*:*:*