CVE-2016-9335

Severity CVSS v4.0:
Pending analysis
Type:
CWE-798 Use of Hard-coded Credentials
Publication date:
09/05/2018
Last modified:
09/10/2019

Description

A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed Industrial switches use hard-coded HTTP SSL/SSH keys for secure communication. Because these keys cannot be regenerated by users, all products use the same key. The attacker could disrupt communication or compromise the system. CVSS v3 base score: 10, CVSS vector string: (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Red Lion Controls recommends updating to SLX firmware Version 5.3.174.

Vulnerable products and versions

CPE From Up to
cpe:2.3:o:redlion:sixnet-managed_industrial_switches_firmware:*:*:*:*:*:*:*:* 5.0.196 (including)
cpe:2.3:h:redlion:sixnet-managed_industrial_switches:-:*:*:*:*:*:*:*
cpe:2.3:o:redlion:stride-managed_ethernet_switches_firmware:*:*:*:*:*:*:*:* 5.0.190 (including)
cpe:2.3:h:redlion:stride-managed_ethernet_switches:-:*:*:*:*:*:*:*


References to Advisories, Solutions, and Tools