CVE-2022-1368

Severity CVSS v4.0:
Pending analysis
Type:
CWE-306 Missing Authentication for Critical Function
Publication date:
06/09/2022
Last modified:
12/09/2022

Description

The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.

Vulnerable products and versions

CPE From Up to
cpe:2.3:o:cognex:3d-a1000_dimensioning_system_firmware:*:*:*:*:*:*:*:* 1.0.3\(3354\) (including)
cpe:2.3:h:cognex:3d-a1000_dimensioning_system:-:*:*:*:*:*:*:*


References to Advisories, Solutions, and Tools