CVE-2022-26335
Severity CVSS v4.0:
Pending analysis
Type:
CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Publication date:
12/04/2022
Last modified:
19/04/2022
Description
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.
Impact
Base Score 3.x
7.50
Severity 3.x
HIGH
Base Score 2.0
7.80
Severity 2.0
HIGH
Vulnerable products and versions
CPE | From | Up to |
---|---|---|
cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:* | 4.1.4 (excluding) | |
cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:* | ||
cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:* | 4.1.4 (excluding) | |
cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:* | ||
cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:* | 4.1.4 (excluding) | |
cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:* | ||
cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:* | 4.1.4 (excluding) | |
cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:* | ||
cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:* | 4.1.4 (excluding) | |
cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:* | ||
cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:* | 4.1.4 (excluding) | |
cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:* | ||
cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:* | 4.1.4 (excluding) | |
cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:* | ||
cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:* | 4.1.4 (excluding) |
To consult the complete list of CPE names with products and versions, see this page