CVE-2023-39459

Severity CVSS v4.0:
Pending analysis
Type:
CWE-22 Path Traversal
Publication date:
03/05/2024
Last modified:
17/06/2025

Description

Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.<br /> <br /> The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of Administrator. Was ZDI-CAN-20531.

Vulnerable products and versions

CPE From Up to
cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3:*:*:*:*:*:*:*