CVE-2023-39464
Severity CVSS v4.0:
Pending analysis
Type:
CWE-428
Unquoted Search Path or Element
Publication date:
03/05/2024
Last modified:
17/06/2025
Description
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.<br />
<br />
The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Impact
Base Score 3.x
7.20
Severity 3.x
HIGH
Vulnerable products and versions
CPE | From | Up to |
---|---|---|
cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:* |
To consult the complete list of CPE names with products and versions, see this page