Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2018-7775

Publication date:
03/07/2018
Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: CVE-2017-9960. Reason: This candidate is a duplicate of CVE-2017-9960. Notes: All CVE users should reference CVE-2017-9960 instead of this candidate. All references and descriptions in this candidate have been removed to prevent accidental usage
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-7774

Publication date:
03/07/2018
The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter.
Severity CVSS v4.0: Pending analysis
Last modification:
21/08/2018

CVE-2018-7778

Publication date:
03/07/2018
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
Severity CVSS v4.0: Pending analysis
Last modification:
05/09/2018

CVE-2018-7776

Publication date:
03/07/2018
The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data.
Severity CVSS v4.0: Pending analysis
Last modification:
28/08/2018

CVE-2018-7786

Publication date:
03/07/2018
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.
Severity CVSS v4.0: Pending analysis
Last modification:
28/08/2018

CVE-2018-7787

Publication date:
03/07/2018
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request.
Severity CVSS v4.0: Pending analysis
Last modification:
28/08/2018

CVE-2018-7777

Publication date:
03/07/2018
The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server.
Severity CVSS v4.0: Pending analysis
Last modification:
03/02/2020

CVE-2018-7782

Publication date:
03/07/2018
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
Severity CVSS v4.0: Pending analysis
Last modification:
03/10/2019

CVE-2018-7785

Publication date:
03/07/2018
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.
Severity CVSS v4.0: Pending analysis
Last modification:
03/10/2019

CVE-2018-7781

Publication date:
03/07/2018
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
Severity CVSS v4.0: Pending analysis
Last modification:
03/10/2019

CVE-2018-7784

Publication date:
03/07/2018
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application.
Severity CVSS v4.0: Pending analysis
Last modification:
30/09/2019

CVE-2018-7780

Publication date:
03/07/2018
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".
Severity CVSS v4.0: Pending analysis
Last modification:
24/05/2019