Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2026-1369

Publication date:
22/02/2026
The Conditional CAPTCHA WordPress plugin through 4.0.0 does not validate a parameter before redirecting the user to its value, leading to an Open Redirect issue
Severity CVSS v4.0: Pending analysis
Last modification:
22/02/2026

CVE-2026-2927

Publication date:
22/02/2026
A vulnerability has been found in D-Link DWR-M960 1.01.07. This vulnerability affects the function sub_462590 of the file /boafrm/formOpMode of the component Operation Mode Configuration Endpoint. The manipulation of the argument submit-url leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity CVSS v4.0: HIGH
Last modification:
22/02/2026

CVE-2026-2928

Publication date:
22/02/2026
A vulnerability was found in D-Link DWR-M960 1.01.07. This issue affects the function sub_452CCC of the file /boafrm/formWlEncrypt of the component WLAN Encryption Configuration Endpoint. The manipulation of the argument submit-url results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.
Severity CVSS v4.0: HIGH
Last modification:
22/02/2026

CVE-2026-2926

Publication date:
22/02/2026
A flaw has been found in D-Link DWR-M960 1.01.07. This affects the function sub_4237AC of the file /boafrm/formLteSetup of the component LTE Configuration Endpoint. Executing a manipulation of the argument submit-url can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
Severity CVSS v4.0: HIGH
Last modification:
22/02/2026

CVE-2026-2925

Publication date:
22/02/2026
A vulnerability was detected in D-Link DWR-M960 1.01.07. Affected by this issue is the function sub_42B5A0 of the file /boafrm/formBridgeVlan of the component Bridge VLAN Configuration Endpoint. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
Severity CVSS v4.0: HIGH
Last modification:
22/02/2026

CVE-2026-2911

Publication date:
22/02/2026
A vulnerability has been found in Tenda FH451 up to 1.0.0.9. This issue affects some unknown processing of the file /goform/GstDhcpSetSer. The manipulation leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Severity CVSS v4.0: HIGH
Last modification:
22/02/2026

CVE-2026-2912

Publication date:
22/02/2026
A vulnerability was found in code-projects Online Reviewer System 1.0. Impacted is an unknown function of the file /system/system/students/assessments/results/studentresult-view.php. The manipulation of the argument test_id results in sql injection. It is possible to launch the attack remotely. The exploit has been made public and could be used.
Severity CVSS v4.0: MEDIUM
Last modification:
22/02/2026

CVE-2026-2913

Publication date:
22/02/2026
A vulnerability was determined in libvips up to 8.19.0. The affected element is the function vips_source_read_to_memory of the file libvips/iofuncs/source.c. This manipulation causes heap-based buffer overflow. It is possible to launch the attack on the local host. The attack's complexity is rated as high. The exploitability is described as difficult. The exploit has been publicly disclosed and may be utilized. Patch name: a56feecbe9ed66521d9647ec9fbcd2546eccd7ee. Applying a patch is the recommended action to fix this issue. The confirmation of the bugfix mentions: "[T]he impact of this is negligible, since this only affects custom seekable sources larger than 4 GiB (and the crash occurs in user code rather than libvips itself)."
Severity CVSS v4.0: LOW
Last modification:
22/02/2026

CVE-2026-2910

Publication date:
22/02/2026
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
Severity CVSS v4.0: HIGH
Last modification:
22/02/2026

CVE-2026-2909

Publication date:
22/02/2026
A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
Severity CVSS v4.0: HIGH
Last modification:
22/02/2026

CVE-2026-2906

Publication date:
22/02/2026
A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Severity CVSS v4.0: HIGH
Last modification:
22/02/2026

CVE-2026-2907

Publication date:
22/02/2026
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
Severity CVSS v4.0: HIGH
Last modification: