Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2025-29923

Publication date:
20/03/2025
go-redis is the official Redis client library for the Go programming language. Prior to 9.5.5, 9.6.3, and 9.7.3, go-redis potentially responds out of order when `CLIENT SETINFO` times out during connection establishment. This can happen when the client is configured to transmit its identity, there are network connectivity issues, or the client was configured with aggressive timeouts. The problem occurs for multiple use cases. For sticky connections, you receive persistent out-of-order responses for the lifetime of the connection. All commands in the pipeline receive incorrect responses. When used with the default ConnPool once a connection is returned after use with ConnPool#Put the read buffer will be checked and the connection will be marked as bad due to the unread data. This means that at most one out-of-order response before the connection is discarded. This issue is fixed in 9.5.5, 9.6.3, and 9.7.3. You can prevent the vulnerability by setting the flag DisableIndentity to true when constructing the client instance.
Severity CVSS v4.0: Pending analysis
Last modification:
15/04/2026

CVE-2025-29215

Publication date:
20/03/2025
Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_43fdcc function at /goform/SetNetControlList.
Severity CVSS v4.0: Pending analysis
Last modification:
25/03/2025

CVE-2025-29914

Publication date:
20/03/2025
OWASP Coraza WAF is a golang modsecurity compatible web application firewall library. Prior to 3.3.3, if a request is made on an URI starting with //, coraza will set a wrong value in REQUEST_FILENAME. For example, if the URI //bar/uploads/foo.php?a=b is passed to coraza: , REQUEST_FILENAME will be set to /uploads/foo.php. This can lead to a rules bypass. This vulnerability is fixed in 3.3.3.
Severity CVSS v4.0: Pending analysis
Last modification:
15/04/2026

CVE-2025-2551

Publication date:
20/03/2025
A vulnerability was found in D-Link DIR-618 and DIR-605L 2.02/3.02. It has been classified as problematic. This affects an unknown part of the file /goform/formSetPortTr. The manipulation leads to improper access controls. Access to the local network is required for this attack. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Severity CVSS v4.0: MEDIUM
Last modification:
14/07/2025

CVE-2025-2552

Publication date:
20/03/2025
A vulnerability was found in D-Link DIR-618 and DIR-605L 2.02/3.02. It has been declared as problematic. This vulnerability affects unknown code of the file /goform/formTcpipSetup. The manipulation leads to improper access controls. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Severity CVSS v4.0: MEDIUM
Last modification:
14/07/2025

CVE-2025-2565

Publication date:
20/03/2025
The data exposure vulnerability in Liferay Portal 7.4.0 through 7.4.3.126, and Liferay DXP 2024.Q3.0, 2024.Q2.0 through 2024.Q2.12, 2024.Q1.1 through 2024.Q1.12, 2023.Q4.0 through 2023.Q4.10, 2023.Q3.1 through 2023.Q3.10, 7.4 GA through update 92 allows an unauthorized user to obtain entry data from forms.
Severity CVSS v4.0: MEDIUM
Last modification:
16/12/2025

CVE-2025-29121

Publication date:
20/03/2025
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.
Severity CVSS v4.0: Pending analysis
Last modification:
28/03/2025

CVE-2025-29149

Publication date:
20/03/2025
Tenda i12 V1.0.0.10(3805) was discovered to contain a buffer overflow via the ping1 parameter in the formSetAutoPing function.
Severity CVSS v4.0: Pending analysis
Last modification:
27/03/2025

CVE-2025-2480

Publication date:
20/03/2025
Santesoft Sante DICOM Viewer Pro is vulnerable to an out-of-bounds write, which requires a user to open a malicious DCM file, resulting in execution of arbitrary code by a local attacker.
Severity CVSS v4.0: HIGH
Last modification:
16/10/2025

CVE-2025-2549

Publication date:
20/03/2025
A vulnerability has been found in D-Link DIR-618 and DIR-605L 2.02/3.02 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /goform/formSetPassword. The manipulation leads to improper access controls. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Severity CVSS v4.0: MEDIUM
Last modification:
15/07/2025

CVE-2025-2550

Publication date:
20/03/2025
A vulnerability was found in D-Link DIR-618 and DIR-605L 2.02/3.02 and classified as problematic. Affected by this issue is some unknown functionality of the file /goform/formSetDDNS of the component DDNS Service. The manipulation leads to improper access controls. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Severity CVSS v4.0: MEDIUM
Last modification:
14/07/2025

CVE-2024-57440

Publication date:
20/03/2025
D-Link DSL-3788 revA1 1.01R1B036_EU_EN is vulnerable to Buffer Overflow via the COMM_MAKECustomMsg function of the webproc cgi