Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2021-38548

Publication date:
11/08/2021
JBL Go 2 devices through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the intensity of a device's power indicator LED is correlative to the power consumption. The sound played by the speakers affects their power consumption and as a result is also correlative to the light intensity of the LEDs. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LEDs of the speakers, we can recover the sound played by them.
Severity CVSS v4.0: Pending analysis
Last modification:
23/08/2021

CVE-2021-38545

Publication date:
11/08/2021
Raspberry Pi 3 B+ and 4 B devices through 2021-08-09, in certain specific use cases in which the device supplies power to audio-output equipment, allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. We assume that the Raspberry Pi supplies power to some speakers. The power indicator LED of the Raspberry Pi is connected directly to the power line, as a result, the intensity of a device's power indicator LED is correlative to the power consumption. The sound played by the speakers affects the Raspberry Pi's power consumption and as a result is also correlative to the light intensity of the LED. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LED of the Raspberry Pi, we can recover the sound played by the speakers.
Severity CVSS v4.0: Pending analysis
Last modification:
23/08/2021

CVE-2021-38547

Publication date:
11/08/2021
Logitech Z120 and S120 speakers through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the intensity of a device's power indicator LED is correlative to the power consumption. The sound played by the speakers affects their power consumption and as a result is also correlative to the light intensity of the LEDs. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LEDs of the speakers, we can recover the sound played by them.
Severity CVSS v4.0: Pending analysis
Last modification:
23/08/2021

CVE-2021-38546

Publication date:
11/08/2021
CREATIVE Pebble devices through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the intensity of a device's power indicator LED is correlative to the power consumption. The sound played by the speakers affects their power consumption and as a result is also correlative to the light intensity of the LEDs. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LEDs of the speakers, we can recover the sound played by them.
Severity CVSS v4.0: Pending analysis
Last modification:
23/08/2021

CVE-2021-38549

Publication date:
11/08/2021
MIRACASE MHUB500 USB splitters through 2021-08-09, in certain specific use cases in which the device supplies power to audio-output equipment, allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. We assume that the USB splitter supplies power to some speakers. The power indicator LED of the USB splitter is connected directly to the power line, as a result, the intensity of the USB splitter's power indicator LED is correlative to its power consumption. The sound played by the connected speakers affects the USB splitter's power consumption and as a result is also correlative to the light intensity of the LED. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LED of the USB splitter, we can recover the sound played by the connected speakers.
Severity CVSS v4.0: Pending analysis
Last modification:
20/08/2021

CVE-2021-38543

Publication date:
11/08/2021
TP-Link UE330 USB splitter devices through 2021-08-09, in certain specific use cases in which the device supplies power to audio-output equipment, allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. We assume that the USB splitter supplies power to some speakers. The power indicator LED of the USB splitter is connected directly to the power line, as a result, the intensity of the USB splitter's power indicator LED is correlative to its power consumption. The sound played by the connected speakers affects the USB splitter's power consumption and as a result is also correlative to the light intensity of the LED. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LED of the USB splitter, we can recover the sound played by the connected speakers.
Severity CVSS v4.0: Pending analysis
Last modification:
23/08/2021

CVE-2021-38544

Publication date:
11/08/2021
Sony SRS-XB33 and SRS-XB43 devices through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the intensity of a device's power indicator LED is correlative to the power consumption. The sound played by the speakers affects their power consumption and as a result is also correlative to the light intensity of the LEDs. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LEDs of the speakers, we can recover the sound played by them.
Severity CVSS v4.0: Pending analysis
Last modification:
23/08/2021

CVE-2021-20420

Publication date:
11/08/2021
IBM Security Guardium 11.2 could disclose sensitive information due to reliance on untrusted inputs that could aid in further attacks against the system. IBM X-Force ID: 196281.
Severity CVSS v4.0: Pending analysis
Last modification:
19/08/2021

CVE-2021-20427

Publication date:
11/08/2021
IBM Security Guardium 11.2 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 196314.
Severity CVSS v4.0: Pending analysis
Last modification:
19/08/2021

CVE-2021-20418

Publication date:
11/08/2021
IBM Security Guardium 11.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 196279.
Severity CVSS v4.0: Pending analysis
Last modification:
19/08/2021

CVE-2021-34640

Publication date:
11/08/2021
The Securimage-WP-Fixed WordPress plugin is vulnerable to Reflected Cross-Site Scripting due to the use of $_SERVER['PHP_SELF'] in the ~/securimage-wp.php file which allows attackers to inject arbitrary web scripts, in versions up to and including 3.5.4.
Severity CVSS v4.0: Pending analysis
Last modification:
19/08/2021

CVE-2019-25052

Publication date:
11/08/2021
In Linaro OP-TEE before 3.7.0, by using inconsistent or malformed data, it is possible to call update and final cryptographic functions directly, causing a crash that could leak sensitive information.
Severity CVSS v4.0: Pending analysis
Last modification:
19/08/2021