Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2021-22809

Publication date:
28/01/2022
A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
Severity CVSS v4.0: Pending analysis
Last modification:
02/02/2022

CVE-2021-22810

Publication date:
28/01/2022
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Severity CVSS v4.0: Pending analysis
Last modification:
04/02/2022

CVE-2021-22725

Publication date:
28/01/2022
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
Severity CVSS v4.0: Pending analysis
Last modification:
28/09/2022

CVE-2021-22724

Publication date:
28/01/2022
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
Severity CVSS v4.0: Pending analysis
Last modification:
28/09/2022

CVE-2016-3735

Publication date:
28/01/2022
Piwigo is image gallery software written in PHP. When a criteria is not met on a host, piwigo defaults to usingmt_rand in order to generate password reset tokens. mt_rand output can be predicted after recovering the seed used to generate it. This low an unauthenticated attacker to take over an account providing they know an administrators email address in order to be able to request password reset.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2022-22868

Publication date:
28/01/2022
Gibbon CMS v22.0.01 was discovered to contain a cross-site scripting (XSS) vulnerability, that allows attackers to inject arbitrary script via name parameters.
Severity CVSS v4.0: Pending analysis
Last modification:
02/02/2022

CVE-2021-41609

Publication date:
28/01/2022
SQL injection in the ID parameter of the UploadedImageDisplay.aspx endpoint of SelectSurvey.NET before 5.052.000 allows a remote, unauthenticated attacker to retrieve data from the application's backend database via boolean-based blind and UNION injection.
Severity CVSS v4.0: Pending analysis
Last modification:
02/02/2022

CVE-2021-41608

Publication date:
28/01/2022
A file disclosure vulnerability in the UploadedImageDisplay.aspx endpoint of SelectSurvey.NET before 5.052.000 allows a remote, unauthenticated attacker to retrieve survey user submitted data by modifying the value of the ID parameter in sequential order beginning from 1.
Severity CVSS v4.0: Pending analysis
Last modification:
12/07/2022

CVE-2021-44971

Publication date:
28/01/2022
Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE.
Severity CVSS v4.0: Pending analysis
Last modification:
14/02/2024

CVE-2021-40395

Publication date:
28/01/2022
Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2021-45898

Publication date:
28/01/2022
SuiteCRM before 7.12.3 and 8.x before 8.0.2 allows local file inclusion.
Severity CVSS v4.0: Pending analysis
Last modification:
02/02/2022

CVE-2021-45899

Publication date:
28/01/2022
SuiteCRM before 7.12.3 and 8.x before 8.0.2 allows PHAR deserialization that can lead to remote code execution.
Severity CVSS v4.0: Pending analysis
Last modification:
02/02/2022