Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2018-5332

Publication date:
11/01/2018
In the Linux kernel through 3.2, the rds_message_alloc_sgs() function does not validate a value that is used during DMA page allocation, leading to a heap-based out-of-bounds write (related to the rds_rdma_extra_size function in net/rds/rdma.c).
Severity CVSS v4.0: Pending analysis
Last modification:
24/02/2023

CVE-2018-0010

Publication date:
10/01/2018
A vulnerability in the Juniper Networks Junos Space Security Director allows a user who does not have SSH access to a device to reuse the URL that was created for another user to perform SSH access. Affected releases are all versions of Junos Space Security Director prior to 17.2R1.
Severity CVSS v4.0: Pending analysis
Last modification:
03/10/2019

CVE-2018-0003

Publication date:
10/01/2018
A specially crafted MPLS packet received or processed by the system, on an interface configured with MPLS, will store information in the system memory. Subsequently, if this stored information is accessed, this may result in a kernel crash leading to a denial of service. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71; 12.3 versions prior to 12.3R12-S7; 12.3X48 versions prior to 12.3X48-D55; 14.1 versions prior to 14.1R8-S5, 14.1R9; 14.1X53 versions prior to 14.1X53-D45, 14.1X53-D107; 14.2 versions prior to 14.2R7-S7, 14.2R8; 15.1 versions prior to 15.1F5-S8, 15.1F6-S8, 15.1R5-S6, 15.1R6-S3, 15.1R7; 15.1X49 versions prior to 15.1X49-D100; 15.1X53 versions prior to 15.1X53-D65, 15.1X53-D231; 16.1 versions prior to 16.1R3-S6, 16.1R4-S6, 16.1R5; 16.1X65 versions prior to 16.1X65-D45; 16.2 versions prior to 16.2R2-S1, 16.2R3; 17.1 versions prior to 17.1R2-S2, 17.1R3; 17.2 versions prior to 17.2R1-S3, 17.2R2; 17.2X75 versions prior to 17.2X75-D50. No other Juniper Networks products or platforms are affected by this issue.
Severity CVSS v4.0: Pending analysis
Last modification:
03/10/2019

CVE-2018-0004

Publication date:
10/01/2018
A sustained sequence of different types of normal transit traffic can trigger a high CPU consumption denial of service condition in the Junos OS register and schedule software interrupt handler subsystem when a specific command is issued to the device. This affects one or more threads and conversely one or more running processes running on the system. Once this occurs, the high CPU event(s) affects either or both the forwarding and control plane. As a result of this condition the device can become inaccessible in either or both the control and forwarding plane and stops forwarding traffic until the device is rebooted. The issue will reoccur after reboot upon receiving further transit traffic. Score: 5.7 MEDIUM (CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H) For network designs utilizing layer 3 forwarding agents or other ARP through layer 3 technologies, the score is slightly higher. Score: 6.5 MEDIUM (CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H) If the following entry exists in the RE message logs then this may indicate the issue is present. This entry may or may not appear when this issue occurs. /kernel: Expensive timeout(9) function: Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D50; 12.3X48 versions prior to 12.3X48-D30; 12.3R versions prior to 12.3R12-S7; 14.1 versions prior to 14.1R8-S4, 14.1R9; 14.1X53 versions prior to 14.1X53-D30, 14.1X53-D34; 14.2 versions prior to 14.2R8; 15.1 versions prior to 15.1F6, 15.1R3; 15.1X49 versions prior to 15.1X49-D40; 15.1X53 versions prior to 15.1X53-D31, 15.1X53-D33, 15.1X53-D60. No other Juniper Networks products or platforms are affected by this issue.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-0014

Publication date:
10/01/2018
Juniper Networks ScreenOS devices do not pad Ethernet packets with zeros, and thus some packets can contain fragments of system memory or data from previous packets. This issue is often detected as CVE-2003-0001. The issue affects all versions of Juniper Networks ScreenOS prior to 6.3.0r25.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-0007

Publication date:
10/01/2018
An unauthenticated network-based attacker able to send a maliciously crafted LLDP packet to the local segment, through a local segment broadcast, may be able to cause a Junos device to enter an improper boundary check condition allowing a memory corruption to occur, leading to a denial of service. Further crafted packets may be able to sustain the denial of service condition. Score: 6.5 MEDIUM (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) Further, if the attacker is authenticated on the target device receiving and processing the malicious LLDP packet, while receiving the crafted packets, the attacker may be able to perform command or arbitrary code injection over the target device thereby elevating their permissions and privileges, and taking control of the device. Score: 7.8 HIGH (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) An unauthenticated network-based attacker able to send a maliciously crafted LLDP packet to one or more local segments, via LLDP proxy / tunneling agents or other LLDP through Layer 3 deployments, through one or more local segment broadcasts, may be able to cause multiple Junos devices to enter an improper boundary check condition allowing a memory corruption to occur, leading to multiple distributed Denials of Services. These Denials of Services attacks may have cascading Denials of Services to adjacent connected devices, impacts network devices, servers, workstations, etc. Further crafted packets may be able to sustain these Denials of Services conditions. Score 6.8 MEDIUM (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H) Further, if the attacker is authenticated on one or more target devices receiving and processing these malicious LLDP packets, while receiving the crafted packets, the attacker may be able to perform command or arbitrary code injection over multiple target devices thereby elevating their permissions and privileges, and taking control multiple devices. Score: 7.8 HIGH (CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H) Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71; 12.3 versions prior to 12.3R12-S7; 12.3X48 versions prior to 12.3X48-D55; 14.1 versions prior to 14.1R8-S5, 14.1R9; 14.1X53 versions prior to 14.1X53-D46, 14.1X53-D50, 14.1X53-D107; 14.2 versions prior to 14.2R7-S9, 14.2R8; 15.1 versions prior to 15.1F2-S17, 15.1F5-S8, 15.1F6-S8, 15.1R5-S7, 15.1R7; 15.1X49 versions prior to 15.1X49-D90; 15.1X53 versions prior to 15.1X53-D65; 16.1 versions prior to 16.1R4-S6, 16.1R5; 16.1X65 versions prior to 16.1X65-D45; 16.2 versions prior to 16.2R2; 17.1 versions prior to 17.1R2. No other Juniper Networks products or platforms are affected by this issue.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2018-0008

Publication date:
10/01/2018
An unauthenticated root login may allow upon reboot when a commit script is used. A commit script allows a device administrator to execute certain instructions during commit, which is configured under the [system scripts commit] stanza. Certain commit scripts that work without a problem during normal commit may cause unexpected behavior upon reboot which can leave the system in a state where root CLI login is allowed without a password due to the system reverting to a "safe mode" authentication state. Lastly, only logging in physically to the console port as root, with no password, will work. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71 on SRX; 12.3X48 versions prior to 12.3X48-D55 on SRX; 14.1 versions prior to 14.1R9; 14.1X53 versions prior to 14.1X53-D40 on QFX, EX; 14.2 versions prior to 14.2R7-S9, 14.2R8; 15.1 versions prior to 15.1F5-S7, 15.1F6-S8, 15.1R5-S6, 15.1R6; 15.1X49 versions prior to 15.1X49-D110 on SRX; 15.1X53 versions prior to 15.1X53-D232 on QFX5200/5110; 15.1X53 versions prior to 15.1X53-D49, 15.1X53-D470 on NFX; 15.1X53 versions prior to 15.1X53-D65 on QFX10K; 16.1 versions prior to 16.1R2. No other Juniper Networks products or platforms are affected by this issue.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-0009

Publication date:
10/01/2018
On Juniper Networks SRX series devices, firewall rules configured to match custom application UUIDs starting with zeros can match all TCP traffic. Due to this issue, traffic that should have been blocked by other rules is permitted to flow through the device resulting in a firewall bypass condition. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71 on SRX series; 12.3X48 versions prior to 12.3X48-D55 on SRX series; 15.1X49 versions prior to 15.1X49-D100 on SRX series.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-0011

Publication date:
10/01/2018
A reflected cross site scripting (XSS) vulnerability in Junos Space may potentially allow a remote authenticated user to inject web script or HTML and steal sensitive data and credentials from a session, and to perform administrative actions on the Junos Space network management device.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-0012

Publication date:
10/01/2018
Junos Space is affected by a privilege escalation vulnerability that may allow a local authenticated attacker to gain root privileges.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-0013

Publication date:
10/01/2018
A local file inclusion vulnerability in Juniper Networks Junos Space Network Management Platform may allow an authenticated user to retrieve files from the system.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-0005

Publication date:
10/01/2018
QFX and EX Series switches configured to drop traffic when the MAC move limit is exceeded will forward traffic instead of dropping traffic. This can lead to denials of services or other unintended conditions. Affected releases are Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D40; 15.1X53 versions prior to 15.1X53-D55; 15.1 versions prior to 15.1R7.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019