Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2019-9055

Publication date:
26/03/2019
An issue was discovered in CMS Made Simple 2.2.8. In the module DesignManager (in the files action.admin_bulk_css.php and action.admin_bulk_template.php), with an unprivileged user with Designer permission, it is possible reach an unserialize call with a crafted value in the m1_allparms parameter, and achieve object injection.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2019-9057

Publication date:
26/03/2019
An issue was discovered in CMS Made Simple 2.2.8. In the module FilePicker, it is possible to reach an unserialize call with an untrusted parameter, and achieve authenticated object injection.
Severity CVSS v4.0: Pending analysis
Last modification:
02/12/2022

CVE-2019-9058

Publication date:
26/03/2019
An issue was discovered in CMS Made Simple 2.2.8. In the administrator page admin/changegroupperm.php, it is possible to send a crafted value in the sel_groups parameter that leads to authenticated object injection.
Severity CVSS v4.0: Pending analysis
Last modification:
02/12/2022

CVE-2019-9061

Publication date:
26/03/2019
An issue was discovered in CMS Made Simple 2.2.8. In the module ModuleManager (in the file action.installmodule.php), it is possible to reach an unserialize call with untrusted input and achieve authenticated object injection by using the "install module" feature.
Severity CVSS v4.0: Pending analysis
Last modification:
02/12/2022

CVE-2014-5401

Publication date:
26/03/2019
Hospira MedNet software version 5.8 and prior uses vulnerable versions of the JBoss Enterprise Application Platform software that may allow unauthenticated users to execute arbitrary code on the target system. Hospira has developed a new version of the MedNet software, MedNet 6.1. Existing versions of MedNet can be upgraded to MedNet 6.1.
Severity CVSS v4.0: Pending analysis
Last modification:
03/11/2025

CVE-2013-2806

Publication date:
26/03/2019
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
Severity CVSS v4.0: Pending analysis
Last modification:
10/02/2020

CVE-2013-2807

Publication date:
26/03/2019
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
Severity CVSS v4.0: Pending analysis
Last modification:
10/02/2020

CVE-2019-7646

Publication date:
26/03/2019
CentOS-WebPanel.com (aka CWP) CentOS Web Panel through 0.9.8.763 is vulnerable to Stored/Persistent XSS for the "Package Name" field via the add_package module parameter.
Severity CVSS v4.0: Pending analysis
Last modification:
24/01/2023

CVE-2018-19856

Publication date:
26/03/2019
GitLab CE/EE before 11.3.12, 11.4.x before 11.4.10, and 11.5.x before 11.5.3 allows Directory Traversal in Templates API.
Severity CVSS v4.0: Pending analysis
Last modification:
28/03/2019

CVE-2014-5431

Publication date:
26/03/2019
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2014-5432

Publication date:
26/03/2019
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2014-5433

Publication date:
26/03/2019
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
Severity CVSS v4.0: Pending analysis