Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2017-9859

Publication date:
05/08/2017
An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This cracked password can then be used to register at the SMA servers. NOTE: the vendor's position is that "we consider the probability of the success of such manipulation to be extremely low." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-9860

Publication date:
05/08/2017
An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the inverter is compromised completely. This allows the attacker to do nearly anything: for example, giving access to the local OS, creating a botnet, using the inverters as a stepping stone into companies, etc. NOTE: the vendor reports that this attack has always been blocked by "a final integrity and compatibility check." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-9864

Publication date:
05/08/2017
An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-9851

Publication date:
05/08/2017
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-9852

Publication date:
05/08/2017
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-9853

Publication date:
05/08/2017
An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of characters. NOTE: the vendor reports that the 12-character limit provides "a very high security standard." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-9854

Publication date:
05/08/2017
An issue was discovered in SMA Solar Technology products. By sniffing for specific packets on the localhost, plaintext passwords can be obtained as they are typed into Sunny Explorer by the user. These passwords can then be used to compromise the overall device. NOTE: the vendor reports that exploitation likelihood is low because these packets are usually sent only once during installation. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-9855

Publication date:
05/08/2017
An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-12562

Publication date:
05/08/2017
Heap-based Buffer Overflow in the psf_binheader_writef function in common.c in libsndfile through 1.0.28 allows remote attackers to cause a denial of service (application crash) or possibly have unspecified other impact.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-7533

Publication date:
05/08/2017
Race condition in the fsnotify implementation in the Linux kernel through 4.12.4 allows local users to gain privileges or cause a denial of service (memory corruption) via a crafted application that leverages simultaneous execution of the inotify_handle_event and vfs_rename functions.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-12419

Publication date:
05/08/2017
If, after successful installation of MantisBT through 2.5.2 on MySQL/MariaDB, the administrator does not remove the 'admin' directory (as recommended in the "Post-installation and upgrade tasks" section of the MantisBT Admin Guide), and the MySQL client has a local_infile setting enabled (in php.ini mysqli.allow_local_infile, or the MySQL client config file, depending on the PHP setup), an attacker may take advantage of MySQL's "connect file read" feature to remotely access files on the MantisBT server.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-12439

Publication date:
05/08/2017
SocuSoft Flash Slideshow Maker Professional through v5.20, when the advanced configuration is used, has an xml_path HTTP parameter that trusts user-supplied input, in conjunction with an unsafe XML configuration file. This has resultant content forgery, cross site scripting, and unvalidated redirection issues.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025