Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2024-12802

Publication date:
09/01/2025
SSL-VPN MFA Bypass in SonicWALL SSL-VPN can arise in specific cases due to the separate handling of UPN (User Principal Name) and SAM (Security Account Manager) account names when integrated with Microsoft Active Directory, allowing MFA to be configured independently for each login method and potentially enabling attackers to bypass MFA by exploiting the alternative account name.
Severity CVSS v4.0: Pending analysis
Last modification:
09/01/2025

CVE-2025-0342

Publication date:
09/01/2025
A vulnerability, which was classified as problematic, was found in CampCodes Computer Laboratory Management System 1.0. This affects an unknown part of the file /class/edit/edit. The manipulation of the argument s_lname leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.
Severity CVSS v4.0: MEDIUM
Last modification:
03/03/2025

CVE-2025-0341

Publication date:
09/01/2025
A vulnerability, which was classified as critical, has been found in CampCodes Computer Laboratory Management System 1.0. Affected by this issue is some unknown functionality of the file /class/edit/edit. The manipulation of the argument e_photo leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity CVSS v4.0: MEDIUM
Last modification:
04/03/2025

CVE-2025-0344

Publication date:
09/01/2025
A vulnerability has been found in leiyuxi cy-fast 1.0 and classified as critical. Affected by this vulnerability is the function listData of the file /commpara/listData. The manipulation of the argument order leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity CVSS v4.0: MEDIUM
Last modification:
22/08/2025

CVE-2024-43660

Publication date:
09/01/2025
The CGI script .sh can be used to download any file on the filesystem.<br /> <br /> This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.<br /> <br /> Likelihood: High, but credentials required.<br /> <br /> Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.<br /> <br /> CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y<br /> CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).
Severity CVSS v4.0: HIGH
Last modification:
09/01/2025

CVE-2024-43659

Publication date:
09/01/2025
After gaining access to the firmware of a charging station, a file at can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.<br /> <br /> This issue affects Iocharger firmware for AC models before firmware version 25010801. <br /> <br /> The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.<br /> <br /> Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using .sh) to gain access to the .json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.<br /> <br /> Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page.<br /> <br /> CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Severity CVSS v4.0: HIGH
Last modification:
09/01/2025

CVE-2024-43661

Publication date:
09/01/2025
The .so library, which is used by , is<br /> vulnerable to a buffer overflow in the code that handles the deletion<br /> of certificates. This buffer overflow can be triggered by providing a<br /> long file path to the action of the .exe CGI binary or<br /> to the .sh CGI script. This binary or script will write this<br /> file path to , which is then<br /> read by .so<br /> <br /> <br /> This issue affects Iocharger firmware for AC models before version 24120701.<br /> <br /> Likelihood: Moderate – An attacker will have to find this exploit by<br /> either obtaining the binaries involved in this vulnerability, or by trial<br /> and error. Furthermore, the attacker will need a (low privilege)<br /> account to gain access to the .exe CGI binary or .sh<br /> script to trigger the vulnerability, or convince a user with such access<br /> send an HTTP request that triggers it.<br /> <br /> <br /> Impact: High – The process, which we assume is<br /> responsible for OCPP communication, will keep crashing after<br /> performing the exploit. This happens because the buffer overflow<br /> causes the process to segfault before<br /> is removed. This means that,<br /> even though is automatically restarted, it will crash<br /> again as soon as it tries to parse the text file.<br /> <br /> CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I).
Severity CVSS v4.0: HIGH
Last modification:
09/01/2025

CVE-2024-43662

Publication date:
09/01/2025
The .exe or .exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user.<br /> <br /> This issue affects Iocharger firmware for AC models before version 24120701.<br /> <br /> Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the .exe or .exe CGI binary and upload the file, or convince a user with such access to upload it.<br /> <br /> Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities.<br /> <br /> CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).
Severity CVSS v4.0: MEDIUM
Last modification:
09/01/2025

CVE-2024-43663

Publication date:
09/01/2025
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.<br /> <br /> Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities.<br /> <br /> Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution.<br /> <br /> CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect  this vulnerability to have a safety impact. The attack can be automated (AU:Y).
Severity CVSS v4.0: MEDIUM
Last modification:
09/01/2025

CVE-2024-43654

Publication date:
09/01/2025
Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root<br /> This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.<br /> <br /> Likelihood: Moderate – The binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the binary, or convince a user with such access to execute a crafted HTTP request.<br /> <br /> Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete<br /> files and services.<br /> <br /> CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Severity CVSS v4.0: CRITICAL
Last modification:
09/01/2025

CVE-2024-43655

Publication date:
09/01/2025
Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root<br /> <br /> This issue affects Iocharger firmware for AC model chargers before version 24120701.<br /> <br /> Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.<br /> <br /> Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.<br /> <br /> CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Severity CVSS v4.0: CRITICAL
Last modification:
09/01/2025

CVE-2024-43656

Publication date:
09/01/2025
Improper Neutralization of Special Elements used in a Command (&amp;#39;Command Injection&amp;#39;) vulnerability allows OS Command Injection as root<br /> <br /> This issue affects Iocharger firmware for AC model chargers before version 24120701.<br /> <br /> Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.<br /> <br /> Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.<br /> <br /> CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Severity CVSS v4.0: CRITICAL
Last modification:
09/01/2025