Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2025-9355

Publication date:
22/08/2025
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this vulnerability is the function scheduleAdd of the file /goform/scheduleAdd. Performing manipulation of the argument ruleName results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity CVSS v4.0: HIGH
Last modification:
02/09/2025

CVE-2025-9356

Publication date:
22/08/2025
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function inboundFilterAdd of the file /goform/inboundFilterAdd. Executing manipulation of the argument ruleName can lead to stack-based buffer overflow. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
Severity CVSS v4.0: HIGH
Last modification:
02/09/2025

CVE-2025-4609

Publication date:
22/08/2025
Incorrect handle provided in unspecified circumstances in Mojo in Google Chrome on Windows prior to 136.0.7103.113 allowed a remote attacker to potentially perform a sandbox escape via a malicious file. (Chromium security severity: High)
Severity CVSS v4.0: Pending analysis
Last modification:
25/08/2025

CVE-2025-26496

Publication date:
22/08/2025
Access of Resource Using Incompatible Type ('Type Confusion') vulnerability in Salesforce Tableau Server, Tableau Desktop on Windows, Linux (File Upload modules) allows Local Code Inclusion.This issue affects Tableau Server, Tableau Desktop: before 2025.1.3, before 2024.2.12, before 2023.3.19.
Severity CVSS v4.0: Pending analysis
Last modification:
04/11/2025

CVE-2025-26497

Publication date:
22/08/2025
Unrestricted Upload of File with Dangerous Type vulnerability in Salesforce Tableau Server on Windows, Linux (Flow Editor modules) allows Absolute Path Traversal.This issue affects Tableau Server: before 2025.1.3, before 2024.2.12, before 2023.3.19.
Severity CVSS v4.0: Pending analysis
Last modification:
06/11/2025

CVE-2025-26498

Publication date:
22/08/2025
Unrestricted Upload of File with Dangerous Type vulnerability in Salesforce Tableau Server on Windows, Linux (establish-connection-no-undo modules) allows Absolute Path Traversal.This issue affects Tableau Server: before 2025.1.3, before 2024.2.12, before 2023.3.19.
Severity CVSS v4.0: Pending analysis
Last modification:
03/11/2025

CVE-2025-43761

Publication date:
22/08/2025
A reflected cross-site scripting (XSS) vulnerability in the Liferay Portal 7.4.0 through 7.4.3.131, and Liferay DXP 2024.Q4.0 through 2024.Q4.4, 2024.Q3.1 through 2024.Q3.13, 2024.Q2.0 through 2024.Q2.13, 2024.Q1.1 through 2024.Q1.12 and 7.4 GA through update 92 allows an remote non-authenticated attacker to inject JavaScript into the frontend-editor-ckeditor-web/ckeditor/samples/old/ajax.html path
Severity CVSS v4.0: MEDIUM
Last modification:
12/12/2025

CVE-2022-45133

Publication date:
22/08/2025
Mahara 21.10 before 21.10.6, 22.04 before 22.04.4, and 22.10 before 22.10.1 allows unsafe font upload for skins. A particularly structured XML file could allow one to traverse the server to obtain access to secure files or cause code execution based on the payload.
Severity CVSS v4.0: Pending analysis
Last modification:
05/09/2025

CVE-2025-57801

Publication date:
22/08/2025
gnark is a zero-knowledge proof system framework. In versions prior to 0.14.0, the Verify function in eddsa.go and ecdsa.go used the S value from a signature without asserting that 0 ≤ S
Severity CVSS v4.0: HIGH
Last modification:
12/09/2025

CVE-2022-31491

Publication date:
22/08/2025
Voltronic Power ViewPower through 1.04-24215, ViewPower Pro through 2.0-22165, and PowerShield Netguard before 1.04-23292 allows a remote attacker to run arbitrary code via an unspecified web interface related to detection of a managed UPS shutting down. An unauthenticated attacker can use this to run arbitrary code immediately regardless of any managed UPS state or presence.
Severity CVSS v4.0: Pending analysis
Last modification:
15/04/2026

CVE-2022-43110

Publication date:
22/08/2025
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
Severity CVSS v4.0: Pending analysis
Last modification:
15/04/2026

CVE-2025-55454

Publication date:
22/08/2025
An authenticated arbitrary file upload vulnerability in the component /msg/sendfiles of DooTask v1.0.51 allows attackers to execute arbitrary code via uploading a crafted file.
Severity CVSS v4.0: Pending analysis
Last modification:
12/09/2025