Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2017-16348

Publication date:
23/08/2018
An exploitable denial of service vulnerability exists in Insteon Hub running firmware version 1012. Leftover demo functionality allows for arbitrarily rebooting the device without authentication. An attacker can send a UDP packet to trigger this vulnerability.
Severity CVSS v4.0: Pending analysis
Last modification:
28/01/2023

CVE-2018-3832

Publication date:
23/08/2018
An exploitable firmware update vulnerability exists in Insteon Hub running firmware version 1013. The HTTP server allows for uploading arbitrary MPFS binaries that could be modified to enable access to hidden resources which allow for uploading unsigned firmware images to the device. To trigger this vulnerability, an attacker can upload an MPFS binary via the '/mpfsupload' HTTP form and later on upload the firmware via a POST request to 'firmware.htm'.
Severity CVSS v4.0: Pending analysis
Last modification:
03/02/2023

CVE-2018-3833

Publication date:
23/08/2018
An exploitable firmware downgrade vulnerability exists in Insteon Hub running firmware version 1013. The firmware upgrade functionality, triggered via PubNub, retrieves signed firmware binaries using plain HTTP requests. The device doesn't check the firmware version that is going to be installed and thus allows for flashing older firmware images. To trigger this vulnerability, an attacker needs to impersonate the remote server 'cache.insteon.com' and serve any signed firmware image.
Severity CVSS v4.0: Pending analysis
Last modification:
03/02/2023

CVE-2018-15685

Publication date:
23/08/2018
GitHub Electron 1.7.15, 1.8.7, 2.0.7, and 3.0.0-beta.6, in certain scenarios involving IFRAME elements and "nativeWindowOpen: true" or "sandbox: true" options, is affected by a WebPreferences vulnerability that can be leveraged to perform remote code execution.
Severity CVSS v4.0: Pending analysis
Last modification:
03/10/2019

CVE-2016-9605

Publication date:
22/08/2018
A flaw was found in cobbler software component version 2.6.11-1. It suffers from an invalid parameter validation vulnerability, leading the arbitrary file reading. The flaw is triggered by navigating to a vulnerable URL via cobbler-web on a default installation.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2017-2575

Publication date:
22/08/2018
A vulnerability was found while fuzzing libbpg 0.9.7. It is a NULL pointer dereference issue due to missing check of the return value of function malloc in the BPG encoder. This vulnerability appeared while converting a malicious JPEG file to BPG.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2017-2635

Publication date:
22/08/2018
A NULL pointer deference flaw was found in the way libvirt from 2.5.0 to 3.0.0 handled empty drives. A remote authenticated attacker could use this flaw to crash libvirtd daemon resulting in denial of service.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-11758

Publication date:
22/08/2018
This affects Apache Cayenne 4.1.M1, 3.2.M1, 4.0.M2 to 4.0.M5, 4.0.B1, 4.0.B2, 4.0.RC1, 3.1, 3.1.1, 3.1.2. CayenneModeler is a desktop GUI tool shipped with Apache Cayenne and intended for editing Cayenne ORM models stored as XML files. If an attacker tricks a user of CayenneModeler into opening a malicious XML file, the attacker will be able to instruct the XML parser built into CayenneModeler to transfer files from a local machine to a remote machine controlled by the attacker. The cause of the issue is XML parser processing XML External Entity (XXE) declarations included in XML. The vulnerability is addressed in Cayenne by disabling XXE processing in all operations that require XML parsing.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-14801

Publication date:
22/08/2018
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-14799

Publication date:
22/08/2018
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-14787

Publication date:
22/08/2018
In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions.
Severity CVSS v4.0: Pending analysis
Last modification:
22/04/2022

CVE-2018-14789

Publication date:
22/08/2018
In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges.
Severity CVSS v4.0: Pending analysis
Last modification: