Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2018-8015

Publication date:
18/05/2018
In Apache ORC 1.0.0 to 1.4.3 a malformed ORC file can trigger an endlessly recursive function call in the C++ or Java parser. The impact of this bug is most likely denial-of-service against software that uses the ORC file parser. With the C++ parser, the stack overflow might possibly corrupt the stack.
Severity CVSS v4.0: Pending analysis
Last modification:
24/08/2020

CVE-2017-18269

Publication date:
18/05/2018
An SSE2-optimized memmove implementation for i386 in sysdeps/i386/i686/multiarch/memcpy-sse2-unaligned.S in the GNU C Library (aka glibc or libc6) 2.21 through 2.27 does not correctly perform the overlapping memory check if the source memory range spans the middle of the address space, resulting in corrupt data being produced by the copy operation. This may disclose information to context-dependent attackers, or result in a denial of service, or, possibly, code execution.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2017-18270

Publication date:
18/05/2018
In the Linux kernel before 4.13.5, a local user could create keyrings for other users via keyctl commands, setting unwanted defaults or causing a denial of service.
Severity CVSS v4.0: Pending analysis
Last modification:
14/08/2020

CVE-2018-11236

Publication date:
18/05/2018
stdlib/canonicalize.c in the GNU C Library (aka glibc or libc6) 2.27 and earlier, when processing very long pathname arguments to the realpath function, could encounter an integer overflow on 32-bit architectures, leading to a stack-based buffer overflow and, potentially, arbitrary code execution.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-11237

Publication date:
18/05/2018
An AVX-512-optimized implementation of the mempcpy function in the GNU C Library (aka glibc or libc6) 2.27 and earlier may write data beyond the target buffer, leading to a buffer overflow in __mempcpy_avx512_no_vzeroupper.
Severity CVSS v4.0: Pending analysis
Last modification:
13/09/2022

CVE-2018-5256

Publication date:
18/05/2018
CoreOS Tectonic 1.7.x before 1.7.9-tectonic.4 and 1.8.x before 1.8.4-tectonic.3 mounts a direct proxy to the kubernetes cluster at /api/kubernetes/ which is accessible without authentication to Tectonic and allows an attacker to directly connect to the kubernetes API server. Unauthenticated users are able to list all Namespaces through the Console, resulting in an information disclosure. Tectonic's exposure of an unauthenticated API endpoint containing information regarding the internal state of the cluster can provide an attacker with information that may assist in other attacks against the cluster. For example, an attacker may not have the permissions required to list all namespaces in the cluster but can instead leverage this vulnerability to enumerate the namespaces and then begin to check each namespace for weak authorization policies that may allow further escalation of privileges.
Severity CVSS v4.0: Pending analysis
Last modification:
18/09/2019

CVE-2018-9250

Publication date:
18/05/2018
interface\super\edit_list.php in OpenEMR before v5_0_1_1 allows remote authenticated users to execute arbitrary SQL commands via the newlistname parameter.
Severity CVSS v4.0: Pending analysis
Last modification:
20/06/2018

CVE-2018-10967

Publication date:
18/05/2018
On D-Link DIR-550A and DIR-604M devices through v2.10KR, a malicious user can forge an HTTP request to inject operating system commands that can be executed on the device with higher privileges, aka remote code execution.
Severity CVSS v4.0: Pending analysis
Last modification:
26/04/2023

CVE-2018-10968

Publication date:
18/05/2018
On D-Link DIR-550A and DIR-604M devices through v2.10KR, a malicious user can use a default TELNET account to get unauthorized access to vulnerable devices, aka a backdoor access vulnerability.
Severity CVSS v4.0: Pending analysis
Last modification:
26/04/2023

CVE-2018-10306

Publication date:
18/05/2018
Services/Form/classes/class.ilDateDurationInputGUI.php and Services/Form/classes/class.ilDateTimeInputGUI.php in ILIAS 5.1.x through 5.3.x before 5.3.4 allow XSS via an invalid date.
Severity CVSS v4.0: Pending analysis
Last modification:
19/06/2018

CVE-2018-10307

Publication date:
18/05/2018
error.php in ILIAS 5.2.x through 5.3.x before 5.3.4 allows XSS via the text of a PDO exception.
Severity CVSS v4.0: Pending analysis
Last modification:
18/06/2018

CVE-2017-9635

Publication date:
18/05/2018
Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019