Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2021-29757

Publication date:
02/08/2021
IBM QRadar User Behavior Analytics 4.1.1 is vulnerable to cross-site request forgery which could allow an attacker to execute malicious and unauthorized actions transmitted from a user that the website trusts. IBM X-Force ID: 202168.
Severity CVSS v4.0: Pending analysis
Last modification:
06/08/2021

CVE-2021-22552

Publication date:
02/08/2021
An untrusted memory read vulnerability in Asylo versions up to 0.6.1 allows an untrusted attacker to pass a syscall number in MessageReader that is then used by sysno() and can bypass validation. This can allow the attacker to read memory from within the secure enclave. We recommend updating to Asylo 0.6.3 or past https://github.com/google/asylo/commit/90d7619e9dd99bcdb6cd28c7649d741d254d9a1a
Severity CVSS v4.0: Pending analysis
Last modification:
10/08/2021

CVE-2021-29741

Publication date:
02/08/2021
IBM AIX 7.1, 7.2, and VIOS 3.1 could allow a local user to exploit a vulnerability in Korn Shell (ksh) to gain root privileges. IBM X-Force ID: 201478.
Severity CVSS v4.0: Pending analysis
Last modification:
12/07/2022

CVE-2021-37840

Publication date:
02/08/2021
aaPanel through 6.8.12 allows Cross-Site WebSocket Hijacking (CSWH) involving OS commands within WebSocket messages at a ws:// URL for /webssh (the victim must have configured Terminal with at least one host). Successful exploitation depends on the browser used by a potential victim (e.g., exploitation can occur with Firefox but not Chrome).
Severity CVSS v4.0: Pending analysis
Last modification:
10/08/2021

CVE-2021-20332

Publication date:
02/08/2021
Specific MongoDB Rust Driver versions can include credentials used by the connection pool to authenticate connections in the monitoring event that is emitted when the pool is created. The user's logging infrastructure could then potentially ingest these events and unexpectedly leak the credentials. Note that such monitoring is not enabled by default. This issue affects MongoDB Rust Driver version 2.0.0-alpha, MongoDB Rust Driver version 2.0.0-alpha1 and MongoDB Rust Driver version 1.0.0 through to and including 1.2.1
Severity CVSS v4.0: Pending analysis
Last modification:
17/09/2024

CVE-2021-37161

Publication date:
02/08/2021
A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote code execution.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2021-37163

Publication date:
02/08/2021
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2021-37162

Publication date:
02/08/2021
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote code execution.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2021-37164

Publication date:
02/08/2021
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a stack-based buffer overflow.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2021-37166

Publication date:
02/08/2021
A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and takes extensive time for the GUI to connect to the TCP socket, allowing the connection to be hijacked by an external attacker.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2021-37160

Publication date:
02/08/2021
A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation (e.g., cryptographic signature validation) during a File Upload for a firmware update.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2021-37167

Publication date:
02/08/2021
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of the functionality of the device.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023