Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2016-8378

Publication date:
13/02/2017
An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application's database lacks sufficient safeguards for protecting credentials.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-8379

Publication date:
13/02/2017
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-8566

Publication date:
13/02/2017
An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-8567

Publication date:
13/02/2017
An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-9332

Publication date:
13/02/2017
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-9333

Publication date:
13/02/2017
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. The SoftCMS Application does not properly sanitize input that may allow a remote attacker access to SoftCMS with administrator's privilege through specially crafted input (SQL INJECTION).
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-9334

Publication date:
13/02/2017
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. User credentials are sent to the web server in clear text, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-9337

Publication date:
13/02/2017
An issue was discovered in Tesla Motors Model S automobile, all firmware versions before version 7.1 (2.36.31) with web browser functionality enabled. The vehicle's Gateway ECU is susceptible to commands that may allow an attacker to install malicious software allowing the attacker to send messages to the vehicle's CAN bus, a Command Injection.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-9338

Publication date:
13/02/2017
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. Exploitation of this vulnerability will still allow the affected device to function in its capacity as a controller.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-9339

Publication date:
13/02/2017
An issue was discovered in INTERSCHALT Maritime Systems VDR G4e Versions 5.220 and prior. External input is used to construct paths to files and directories without properly neutralizing special elements within the pathname that could allow an attacker to read files on the system, a Path Traversal.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-9343

Publication date:
13/02/2017
An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2016-9344

Publication date:
13/02/2017
An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. An attacker may be able to brute force an active session cookie to be able to download configuration files.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026