Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2017-15342

Publication date:
15/02/2018
Huawei DP300 V500R002C00, TE60 V600R006C00, TP3106 V100R002C00, eSpace U1981 V200R003C30SPC100 have a denial of service vulnerability. The software does not correctly calculate the rest size in a buffer when handling SSL connections. A remote unauthenticated attacker could send a lot of crafted SSL messages to the device, successful exploit could cause no space in the buffer and then denial of service.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-15343

Publication date:
15/02/2018
Huawei AR3200 with software V200R006C10, V200R006C11, V200R007C00, V200R007C01, V200R007C02, V200R008C00, V200R008C10, V200R008C20, V200R008C30 has an integer overflow vulnerability. The software does not sufficiently validate certain field in SCTP messages, a remote unauthenticated attacker could send a crafted SCTP message to the device. Successful exploit could system reboot.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-15344

Publication date:
15/02/2018
Huawei AR3200 with software V200R006C10, V200R006C11, V200R007C00, V200R007C01, V200R007C02, V200R008C00, V200R008C10, V200R008C20, V200R008C30 has an integer overflow vulnerability. The software does not sufficiently validate certain field in SCTP messages, a remote unauthenticated attacker could send a crafted SCTP message to the device. Successful exploit could cause system reboot.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-18087

Publication date:
15/02/2018
The download commit resource in Atlassian Bitbucket Server from version 5.1.0 before version 5.1.7, from version 5.2.0 before version 5.2.5, from version 5.3.0 before version 5.3.3 and from version 5.4.0 before version 5.4.1 allows remote attackers to write files to disk potentially allowing them to gain code execution, exploit CVE-2017-1000117 if a vulnerable version of git is in use, and or determine if an internal service exists via an argument injection vulnerability in the at parameter.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-18088

Publication date:
15/02/2018
Various plugin servlet resources in Atlassian Bitbucket Server before version 5.3.7 (the fixed version for 5.3.x), from version 5.4.0 before 5.4.6 (the fixed version for 5.4.x), from version 5.5.0 before 5.5.6 (the fixed version for 5.5.x), from version 5.6.0 before 5.6.3 (the fixed version for 5.6.x), from version 5.7.0 before 5.7.1 (the fixed version for 5.7.x) and before 5.8.0 allow remote attackers to conduct clickjacking attacks via framing various resources that lacked clickjacking protection.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-12718

Publication date:
15/02/2018
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-12720

Publication date:
15/02/2018
An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-12721

Publication date:
15/02/2018
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-12722

Publication date:
15/02/2018
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-12723

Publication date:
15/02/2018
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-12724

Publication date:
15/02/2018
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026

CVE-2017-12725

Publication date:
15/02/2018
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.
Severity CVSS v4.0: Pending analysis
Last modification:
17/06/2026