Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2018-16282

Publication date:
20/09/2018
A command injection vulnerability in the web server functionality of Moxa EDR-810 V4.2 build 18041013 allows remote attackers to execute arbitrary OS commands with root privilege via the caname parameter to the /xml/net_WebCADELETEGetValue URI.
Severity CVSS v4.0: Pending analysis
Last modification:
05/11/2018

CVE-2018-16752

Publication date:
20/09/2018
LINK-NET LW-N605R devices with firmware 12.20.2.1486 allow Remote Code Execution via shell metacharacters in the HOST field of the ping feature at adm/systools.asp. Authentication is needed but the default password of admin for the admin account may be used in some cases.
Severity CVSS v4.0: Pending analysis
Last modification:
03/10/2019

CVE-2018-6504

Publication date:
20/09/2018
A potential Cross-Site Request Forgery (CSRF) vulnerability has been identified in ArcSight Management Center (ArcMC) in all versions prior to 2.81. This vulnerability could be exploited to allow for Cross-Site Request Forgery (CSRF).
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-6505

Publication date:
20/09/2018
A potential Unauthenticated File Download vulnerability has been identified in ArcSight Management Center (ArcMC) in all versions prior to 2.81. This vulnerability could be exploited to allow for Unauthenticated File Downloads.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-14821

Publication date:
20/09/2018
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-14827

Publication date:
20/09/2018
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-14829

Publication date:
20/09/2018
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-6502

Publication date:
20/09/2018
A potential Reflected Cross-Site Scripting (XSS) Security vulnerability has been identified in ArcSight Management Center (ArcMC) in all versions prior to 2.81. This vulnerability could be exploited to allow for Reflected Cross-site Scripting (XSS).
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-6503

Publication date:
20/09/2018
A potential Access Control vulnerability has been identified in ArcSight Management Center (ArcMC) in all versions prior to 2.81. This vulnerability could be exploited to allow for vulnerable Access Controls.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-14796

Publication date:
20/09/2018
Tec4Data SmartCooler, all versions prior to firmware 180806, the device responds to a remote unauthenticated reboot command that may be used to perform a denial of service attack.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-6501

Publication date:
20/09/2018
Potential security vulnerability of Insufficient Access Controls has been identified in ArcSight Management Center (ArcMC) for versions prior to 2.81. This vulnerability could be exploited to allow for insufficient access controls.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023

CVE-2018-6500

Publication date:
20/09/2018
A potential Directory Traversal Security vulnerability has been identified in ArcSight Management Center (ArcMC) in all versions prior to 2.81. This vulnerability could be remotely exploited to allow Directory Traversal.
Severity CVSS v4.0: Pending analysis
Last modification:
07/11/2023