Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2018-8844

Publication date:
26/09/2018
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-8846

Publication date:
26/09/2018
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-8848

Publication date:
26/09/2018
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.
Severity CVSS v4.0: Pending analysis
Last modification:
29/09/2020

CVE-2018-14803

Publication date:
26/09/2018
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to the attacker, but might be useful information in an attack.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-8842

Publication date:
26/09/2018
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019

CVE-2018-10602

Publication date:
26/09/2018
WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple stack-based buffer overflow vulnerabilities that can be exploited when the application processes specially crafted project files.
Severity CVSS v4.0: Pending analysis
Last modification:
28/08/2020

CVE-2018-10606

Publication date:
26/09/2018
WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple heap-based buffer overflow vulnerabilities that can be exploited when the application processes specially crafted project files.
Severity CVSS v4.0: Pending analysis
Last modification:
28/08/2020

CVE-2018-15606

Publication date:
26/09/2018
An XSS issue was discovered in SalesAgility SuiteCRM 7.x before 7.8.21 and 7.10.x before 7.10.8, related to phishing an error message.
Severity CVSS v4.0: Pending analysis
Last modification:
15/11/2018

CVE-2018-16672

Publication date:
26/09/2018
An issue was discovered in CIRCONTROL CirCarLife before 4.3. Due to the storage of multiple sensitive information elements in a JSON format at /services/system/setup.json, an authenticated but unprivileged user can exfiltrate critical setup information.
Severity CVSS v4.0: Pending analysis
Last modification:
08/07/2021

CVE-2018-7355

Publication date:
26/09/2018
All versions up to V1.0.0B05 of ZTE MF65 and all versions up to V1.0.0B02 of ZTE MF65M1 are impacted by cross-site scripting vulnerability. Due to improper neutralization of input during web page generation, an attacker could exploit this vulnerability to conduct reflected XSS or HTML injection attacks on the devices.
Severity CVSS v4.0: Pending analysis
Last modification:
10/01/2019

CVE-2018-1785

Publication date:
26/09/2018
IBM Tivoli Storage Manager (IBM Spectrum Protect 7.1 and 8.1) uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt sensitive information. IBM X-Force ID: 148870.
Severity CVSS v4.0: Pending analysis
Last modification:
20/11/2021

CVE-2018-1683

Publication date:
26/09/2018
IBM WebSphere Application Server Liberty could allow a remote attacker to obtain sensitive information, caused by the failure to encrypt ORB communication. IBM X-Force ID: 145455.
Severity CVSS v4.0: Pending analysis
Last modification:
09/10/2019