Vulnerabilities

With the aim of informing, warning and helping professionals with the latest security vulnerabilities in technology systems, we have made a database available for users interested in this information, which is in Spanish and includes all of the latest documented and recognised vulnerabilities.

This repository, with over 75,000 registers, is based on the information from the NVD (National Vulnerability Database) – by virtue of a partnership agreement – through which INCIBE translates the included information into Spanish.

On occasions this list will show vulnerabilities that have still not been translated, as they are added while the INCIBE team is still carrying out the translation process. The CVE  (Common Vulnerabilities and Exposures) Standard for Information Security Vulnerability Names is used with the aim to support the exchange of information between different tools and databases.

All vulnerabilities collected are linked to different information sources, as well as available patches or solutions provided by manufacturers and developers. It is possible to carry out advanced searches, as there is the option to select different criteria to narrow down the results, some examples being vulnerability types, manufacturers and impact levels, among others.

Through RSS feeds or Newsletters we can be informed daily about the latest vulnerabilities added to the repository. Below there is a list, updated daily, where you can discover the latest vulnerabilities.

CVE-2017-10670

Publication date:
30/06/2017
An XML External Entity (XXE) issue exists in OSCI-Transport 1.2 as used in OSCI Transport Library 1.6.1 (Java) and OSCI Transport Library 1.6 (.NET), exploitable by sending a crafted standard-conforming OSCI message from within the infrastructure.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-10668

Publication date:
30/06/2017
A Padding Oracle exists in OSCI-Transport 1.2 as used in OSCI Transport Library 1.6.1 (Java) and OSCI Transport Library 1.6 (.NET). Under an MITM condition within the OSCI infrastructure, an attacker needs to send crafted protocol messages to analyse the CBC mode padding in order to decrypt the transport encryption.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-7901

Publication date:
30/06/2017
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-7903

Publication date:
30/06/2017
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-6026

Publication date:
30/06/2017
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-6028

Publication date:
30/06/2017
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-6030

Publication date:
30/06/2017
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-6034

Publication date:
30/06/2017
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-6036

Publication date:
30/06/2017
A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web server receives a request, but does not sufficiently verify that the request is being sent to the expected destination.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-6038

Publication date:
30/06/2017
A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-6040

Publication date:
30/06/2017
An Information Exposure issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. Non-sensitive information can be obtained anonymously.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025

CVE-2017-6042

Publication date:
30/06/2017
A Cross-Site Request Forgery issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Affected devices do not verify if a request was intentionally sent by the logged-in user, which may allow an attacker to trick a client into making an unintentional request to the web server that will be treated as an authentic request.
Severity CVSS v4.0: Pending analysis
Last modification:
20/04/2025